Reimbursement and use of intensity-modulated radiation therapy for prostate cancer
نویسندگان
چکیده
The use of intensity-modulated radiation therapy (IMRT) for prostate cancer increased through the mid-2000s, in association with acquisition of the devices by large urology groups. More recently, reimbursement for IMRT in the office setting (generally representing freestanding facilities owned by physicians) has been declining. The aim of the study was to examine trends in IMRT use and related payments in the office versus hospital outpatient setting over time.In this retrospective cohort study, a total of 66,967 men aged 66 years or older, with newly diagnosed prostate cancer from 2007 through 2012 were identified in a 20% national sample of Medicare claims. IMRT use in the office versus hospital outpatient setting was examined over time, adjusted for patient characteristics using multivariable logistic regression models. Mean reimbursement for IMRT treatments and total IMRT-related payments were plotted by year.IMRT use increased from 28.6% to 38.0% of newly diagnosed men with prostate cancer over the study period, exclusively related to growth in the office setting. In particular, use in the office setting increased from 13.2% in 2007 to 22.1%, whereas use in the hospital outpatient setting remained essentially steady throughout the period around 15%. During the same period mean reimbursement for IMRT in the office setting declined from $504 per individual radiation treatment to $381, whereas it increased from $283 to $380 in the hospital outpatient setting. However, total IMRT-related payments in the office setting increased through 2011 due to increased utilization, falling only in 2012 (to $35.7 million from $48.3 million in 2011) related both to continued declines in reimbursement and a large reduction in new cases of prostate cancer.In conclusion, use of IMRT in the physician office setting in men diagnosed with prostate cancer has continued to increase in the face of declining reimbursement. Total payments for IMRT fell only in 2012, following a substantial reduction in new cases of prostate cancer.
منابع مشابه
Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملThe Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters
Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...
متن کاملOut-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer
Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...
متن کاملStep-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملEarly toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2017