Experimental Apparatus for Measuring the Performance of a Precooled Mixed Gas Joule Thomson Cryosurgical Probe
نویسنده
چکیده
Cryosurgery is a technique for destroying undesirable tissue such as cancers using a freezing process. A previous paper referenced here describes the development of a thermodynamic modeling tool for a precooled Mixed Gas Joule-Thomson (MGJT) cryoprobe used for cryosurgery. An experimental test facility has been constructed to capture the performance of a precooled MGJT cryoprobe; the experimental data will be used to tune and verify the model. The test facility is flexible relative to working fluid, charge pressure, pressure ratio, and flow rate. Therefore, the facility can also be used to demonstrate additional cooling capacity available with the optimal mixture compositions and operating parameters selected by the model. A commercially available cryoprobe system has been disassembled and installed in a vacuum insulated dewar. The system has been modified in order to integrate a suite of measurement instrumentation that can completely characterize the performance of individual components as well as the overall system. Measurements include sufficient temperature and pressure sensors to resolve thermodynamic states and flow meters to calculate heat and work transfer rates. A thermal load is applied to the cycle using an electric heater to characterize the refrigeration performance. Temperature sensors are also integrated within the recuperator in order to capture the heat transfer performance of the two-phase, multi-component mixture as it flows through the recuperator. An uncertainty analysis for the experiment is presented in this paper and shows that the performance metrics can be computed from the experimental data to within 10% uncertainty under the nominal anticipated operating conditions using both a synthetic refrigerant and hydrocarbon based gas mixture. Preliminary data are reduced to demonstrate the capability of the test facility.
منابع مشابه
A Correlation for the Prediction of the Adiabatic Joule-Thomson Coefficient of Pure Gases and Gas Mixtures
A correlation based on the general form of cubic equations of state has been derived. This equation provides a convenient mathematical form of the Joule-Thomson coefficient in terms of the state variable V and T. The Joule-Thomson coefficient calculated by this correlation has been compared with experimental data. It has been shown that the Redilich-Kwang equation of state is a suitable equ...
متن کاملTransient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملPredictions of the Joule-Thomson Inversion Curve for Water and Methanol from the LJ-SAFT EOS
In this work, we have calculated the Joule-Thomson inversion curve of two important associating fluids, namely water and methanol, from the SAFT equation of state. Comparisons with the available experimental data, for water and methanol indicate that this molecular based equation of state gives good prediction of the low temperature branch; but, unfortunately, due to lack of isenthalpic dat...
متن کاملInfluence of unsuitable operational conditions on the transient performance of a small hydrogen liquefier
Joule-Thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. Although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. In the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic Joule-Thomson cooling system...
متن کاملMicromachined Heat Exchanger for a Cryosurgical Probe
This paper describes a lithography-based microfabrication process developed for a recuperative heat exchanger intended for use in a cryosurgical probe. The probe, which uses the Joule-Thomson (JT) cooling cycle, must achieve a temperature < -50°C, with a freeze rate of 25-50°C/min. The heat exchanger must maintain high stream-to-stream thermal conductance while restricting parasitic stream-wise...
متن کامل