Goldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes.

نویسندگان

  • Yakov Goldich
  • Yaniv Barkana
  • Isaac Avni
  • David Zadok
چکیده

PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a corneal correlated IOP (IOPcc). Assessment of refractive status, visual acuity, axial length, corneal topography, and pachymetry was done. RESULTS Fifty-nine eyes of 59 patients with KC (39 men, 20 women; mean age: 27.8 +/- 6.8 years) were included. The differences in mean IOP values between GAT (10.9 +/- 2.0 mm Hg) and IOPg (9.5 +/- 2.8 mm Hg) and between GAT and IOPcc (13.3 +/- 2.5 mm Hg) were statistically significant (all P < 0.001). Both pressure measurements provided by the ORA showed significant correlation with corneal curvature. No significant effect of corneal thickness on any of the pressures was observed. CONCLUSIONS IOP measurements taken with GAT and ORA in keratoconic eyes were significantly different. Although IOPcc was significantly higher, IOPg was significantly lower than GAT IOP. Unlike GAT measurements, ORA readings seemed to be affected mainly by corneal curvature. As a result of described differences, we suggest these devices should not be used interchangeably but rather in a complementary fashion to assess IOP in keratoconic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements.

PURPOSE To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central cornea...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

CLINICAL SCIENCE Can We Measure Corneal Biomechanical Changes After Collagen Cross-Linking in Eyes With Keratoconus?—A Pilot Study

Methods: Ten eyes of 10 patients aged 26.5 6 5.7 (mean 6 SD) years with progressive keratoconus were treated with UV-A– riboflavin CXL and assessed with the Ocular Response Analyzer (ORA) that measured corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated intraocular pressure (IOPcc). Intraocular pressure was also meas...

متن کامل

Higher incidence of steroid-induced ocular hypertension in keratoconus

BACKGROUND To compare intraocular pressure (IOP) changes following topical dexamethasone administration for 1 month in keratoconic versus normal eyes. METHODS This is a retrospective, single-center, non-randomized case series evaluation of 350 eyes. Two groups were formed: normal/control Group A (nA =73), eyes that underwent excimer laser photorefractive keratectomy; and keratoconic (KCN) Gro...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2010