Determination of catecholamines and related compounds in mouse urine using column-switching HPLC.

نویسندگان

  • Takahiro Kanamori
  • Takashi Funatsu
  • Makoto Tsunoda
چکیده

We have developed an analytical method for the determination of catecholamines and related compounds in mouse urine by column-switching HPLC. Selective extraction of the catechol compounds was performed using a precolumn modified with phenylboronic acid, which has a pH dependent affinity for the catechol structures. The pretreatment buffer, which facilitated binding of the catechols to the precolumn, was optimized to ensure high analyte recoveries and good peak shapes. We found that using the same acetonitrile content in the pretreatment buffer and hydrophilic interaction liquid chromatography mobile phase was necessary to improve peak shapes. Eight catechol compounds were selectively extracted and separated using 100 mmol L(-1) ammonium formate/acetonitrile (20/80 v/v, pH 8.0) for the extraction step, and 20 mmol L(-1) ammonium formate (pH 2.5)/acetonitrile (20/80 v/v) for elution and separation. Native fluorescence of the separated catechol compounds was monitored, and the limits of detection, corresponding to a signal to noise ratio of 3, were 9-58 nmol L(-1). Five catechol compounds (dopamine, epinephrine, norepinephrine, 3,4-dihydroxyphenylglycol, and 3,4-dihydroxymandelic acid) were successfully quantified in mouse urine. Intra- and inter-day precisions were less than 10%, and performance was superior to that afforded by manual sample pretreatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coupled-column liquid chromatographic analysis of catecholamines, serotonin, and metabolites in human urine.

A column-switching HPLC system was utilized for the simultaneous determination of epinephrine, norepinephrine, dopamine, serotonin, and their metabolites metanephrine, normetanephrine, 3, 4-dihydroxyphenylacetic acid, homovanillic acid, and 5-hydroxyindoleacetic acid in human urine. The sample was injected directly onto a C18-alkyl-diol silica precolumn, which separated the analytes from matrix...

متن کامل

Determination of free catecholamines in urine by tandem affinity/ion-pair chromatography and flow injection analysis.

BACKGROUND A system was developed for the simultaneous measurement in urine of free catecholamines (i.e., dopamine, norepinephrine, epinephrine) and creatinine (i.e., an indicator of urine output and volume). This method was based on the use of tandem affinity/ion-pair HPLC and flow injection analysis. METHODS The free catecholamines were extracted directly from urine by using an on-line phen...

متن کامل

Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples

In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...

متن کامل

Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples

In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...

متن کامل

The Development of a Column-Switching High-Performance Liquid Chromatograph System for Chiral Separation of Mouse Urinary D, L-Lactate

Two high-performance liquid chromatograph (HPLC) systems with a Rheodyne Model 7000 switching valve for separation of Dand L-lactate in biological samples has been reported. However, since the switching valve was rotated manually, so that only 10 samples could be determined within one day. For better efficiency, a circuit for rotating the switching valve automatically, which is including mechan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 141 8  شماره 

صفحات  -

تاریخ انتشار 2016