A Multi-leaf Faraday Cup Especially for Proton Therapy of Ocular Tumors

نویسندگان

  • S. Seidel
  • C. Kunert
  • J. Bundesmann
  • T. Damerow
چکیده

For radiation therapy with protons knowing the beam range with high accuracy is crucial. The Multi-leaf Faraday Cup (MLFC) allows a quick and precise range measurement of the full radiation field in air. In the field of eye tumor therapy an accuracy in the submillimeter regime is required. We present an MLFC with 47 channels which can be read out simultaniuosly. Each channel consists of a 10 μm copper foil, connected to an ammeter, next to a 25 μm kapton foil. An automated preabsorber system allows range measurements in different energy regions. The achievable relative resolution of 50 μm in water meets the desired accuracy for eye tumor therapy. Furthermore is is possible to gain information about the dose distribution in water for quality assurance measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Multi-leaf Faraday Cup Especially for the Therapy of Ocular Tumors with Protons

For tumor therapy with protons it is crucial to know the beam range with high accuracy. The Multi-leaf Faraday Cup (MLFC) offers a quick and precise range and energy measurement. Our MLFC is adapted to the eye tumor therapy requirements and has 47 channels; each consists of a 10 μm copper foil (connected to an ammeter) next to a 25 μm KaptonTM foil. A system of absorbers has been constructed to...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma

In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...

متن کامل

Proton beam dosimetry: a comparison between a plastic scintillator, ionization chamber and Faraday cup.

In this study, a comparison was made between a plastic scintillator (BC400), a Faraday Cup (FC) and an ionization chamber (IC) used for routine proton dosimetry. Thin scintillators can be applied to proton dosimetry and consequently to proton therapy as relative dosimeters because of their water-equivalent nature, high energy-light conversion efficiency, low dimensions and good proportionality ...

متن کامل

Consider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.

Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013