Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients.
نویسندگان
چکیده
INTRODUCTION This study compares the outcome and complications of integrated hydroxyapatite implant and non-integrated orbital implants following enucleation in Asian patients. MATERIALS AND METHODS This is a retrospective study of enucleated patients with coralline hydroxyapatite implants versus non-integrated implants (acrylic, glass and silicone) at the Singapore National Eye Centre from January 1991 to December 2000. The outcomes measured were implant migration, extrusion, socket infection, conjunctival dehiscence and implant exposure. Statistical analysis was done using the 2-sample t-test. RESULTS Twenty-one patients had the hydroxyapatite implant and 38 non-integrated implants (27 acrylic, 9 glass and 2 silicone). The mean duration of follow-up was 2.7 years and 4 years for the hydroxyapatite implant and non-integrated implants respectively. Three patients with pre-existing severe socket contracture before enucleation surgeries were excluded from the study. Four cases of implant migration, 4 cases of implant extrusion and 3 cases of socket infection were encountered; all were sockets fitted with non-integrated implants. There was a higher rate of conjunctival dehiscence for sockets with hydroxyapatite implants (6 out of 21) compared to sockets with non-integrated implants (3 out of 35). This was statistically significant (P = 0.048). CONCLUSIONS Implant complications of migration, extrusion and socket infection were found in non-integrated implants and none in coralline hydroxyapatite implants, which had a significantly higher rate of conjunctival dehiscence. Most of these were easily managed with only a small number progressing to implant exposure.
منابع مشابه
Topographic measurements of eyelids and orbit in enucleated eyes with hydroxyapatite integrated implant versus PMMA implant
INTRODUCTION This study reports our results relating to palpebral eyelid fissure and orbital measurements following evisceration with orbital implantation of hydroxyapatite integrated implant and PMMA implant. MATERIALS AND METHODS This study is a prospective study of 43 patients that underwent evisceration for different ocular affections at University Emergency Hospital Bucharest, Ophthalmol...
متن کاملHydroxyapatite ocular implant and non-integrated implants in eviscerated patients
INTRODUCTION This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. MATERIALS AND METHODS This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and Decembe...
متن کاملMobility of hydroxyapatite orbital implant covered with autologous sclera.
PURPOSE To evaluate the mobility of a hydroxyapatite implant covered with autologous sclera from the enucleated globes of patients with severe atrophy of the eyeball or eyelid retraction. METHODS This implant was used in seven patients with phthisis bulbi. We measured the movement of the implant by photographic analysis of the anterior orbit and by using a strain gauge. RESULTS At 1-3 years...
متن کاملHistologic evaluation of hydroxyapatite-coated root-form implant retrieved after 7 years in function: a case report.
This case report presents a clinical, radiographic, and histologic evaluation of 2 non-adjacent, hydroxyapatite-coated, root-form implants retrieved from the maxillary canine area of a patient after 7 years in function. Clinical examination revealed immobile implants with no sign of pathosis. Radiographic examination indicated close proximity of the bone to the implant surface without evidence ...
متن کاملComparative Study of Bone Repair Using Porous Hydroxyapatite/ β-Tricalcium Phosphate and Xenograft Scaffold in Rabbits with Tibia Defect
Background: Bone tissue engineering requires materials that are biocompatible, mechanically suited for bone function, integrated with the host skeleton, and support osteoinduction of the implanted cells for new bone formation. The aim of this study was to compare the osteogenic potential of xenograft with hydroxyapatite/β- tricalcium phosphate (HA/β-TCP) scaffold. Methods: New Zealand rabbits (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of the Academy of Medicine, Singapore
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2004