A new non-invasive estimation of the stenotic aortic valve area by pulsed Doppler mapping.
نویسندگان
چکیده
A new pulsed Doppler mapping technique has been used to measure the severity of aortic valve stenosis. The Doppler examination was performed at the site of the aortic orifice in the parasternal short axis echocardiographic view and the method was based on the detection of the area of systolic flow through the stenotic orifice. This area was derived by planimetry and the measurements obtained by the Doppler method were compared with the aortic valve area calculated at catheterisation according to the Gorlin formula. The method was applicable in 41 of the 44 patients studied. The Doppler data were consistent with the haemodynamic measurements even in patients with decreased cardiac index. It is concluded that this new application of the flow mapping procedure is reliable and is easily applied to adult patients with a wide range of clinical conditions.
منابع مشابه
Stenotic Aortic Valve Area
I n aortic stenosis, the aortic valve area (AVA) is intuitively the most appealing measure of severity because it is supposed to be (largely) independent of stroke volume and left ventricular pump function and reflects most closely “stenosis.” Calculation of the AVA by the continuity equation is routinely performed in echocardiography (1), using 3 measurements: the velocity-time integral of the...
متن کاملAssessment of pulsed Doppler echocardiography in detection and quantification of aortic and mitral regurgitation.
Pulsed Doppler echocardiography was employed to detect disturbed or turbulent flow diagnostic of aortic or mitral regurgitation. Sensitivity, specificity, diagnostic accuracy, and predictive value were assessed by the independent interpretation and comparison of aortic root angiograms (91 patients) and left ventriculograms (94 patients) to the time interval histogram display of the pulsed Doppl...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملVariation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: comparison with traditional Doppler data.
OBJECTIVES Flow variations can affect valve-area calculation in aortic stenosis and lead to inaccuracies in the evaluation of the stenosis. Knowing that transvalvular flow varies normally within one beat, we designed this study to assess the response of the valve to intrabeat variation of flow during systole. Results were compared with flow-derived measurements. BACKGROUND Technological impro...
متن کاملDoppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula.
Thirty adult patients with aortic stenosis had Doppler echocardiography within 1 day of cardiac catheterization. Noninvasive measurement of the mean transaortic pressure gradient was calculated by applying the simplified Bernoulli equation to the continuous wave Doppler transaortic velocity recording. Stroke volume was measured noninvasively by multiplying the systolic velocity integral of flow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 57 1 شماره
صفحات -
تاریخ انتشار 1987