Revisiting Ciliary Muscle Tendons and Their Connections With the Trabecular Meshwork by Two Photon Excitation Microscopic Imaging.
نویسندگان
چکیده
PURPOSE To elucidate the anatomy of the trabecular meshwork (TM) and its connection to ciliary muscle (CM) tendons with two photon excitation microscopic (TPEM) imaging. METHODS The human aqueous outflow pathway was imaged in an unfixed and nonembeded state by using an inverted TPEM. Laser (Ti:Sapphire) was tuned at 850 nm for emission. Backscatter signals of second harmonic generation (SHG) and autofluorescence (AF) were collected through 425/30-nm and 525/45 emission filters, respectively. Multiple, consecutive, and overlapping image stacks (z-stacks) were acquired to generate three-dimensional data sets. RESULTS Collagen and elastin structures of the TM were successfully visualized with TPEM. The TM and CM tendons were found to contain both collagen and elastin fibers. What appears to be juxtacanalicular tissue (JCT) was identified by its honeycomb-like appearance in AF images. Tracing CM tendons from their origins and to their insertions revealed that elastin fibers of CM tendons were connected to the elastin network within the trabecular lamellae. The CM tendons converged or diverged along their course, forming intricate networks with the TM. The CM tendon fiber density varied depending on its location within the aqueous outflow pathway with tendons near the JCT found to be the most dense, and in a fine-tooth comb arrangement. CONCLUSIONS By using TPEM imaging, new details of the human aqueous outflow pathway were elucidated. This high-resolution imaging technique revealed the intricate interconnections between the TM and CM tendons.
منابع مشابه
The structure of the trabecular meshwork, its connections to the ciliary muscle, and the effect of pilocarpine on outflow facility in mice.
PURPOSE To determine the connections between the ciliary muscle (CM), trabecular meshwork (TM), and Schlemm's canal (SC) and their innervations that allows CM contraction (by pilocarpine) to influence conventional outflow in mice. METHODS Sequential sections and whole mounts of murine corneoscleral angles were stained for elastin, α-smooth muscle actin (αSMA), vesicular acetylcholine transpor...
متن کاملRole of protein tyrosine kinase on regulation of trabecular meshwork and ciliary muscle contractility.
PURPOSE Trabecular meshwork and ciliary muscle express properties of smooth muscle cells. The contractility of trabecular meshwork and ciliary muscle is differently modulated by various agents. To reveal contractile regulatory processes, the effects of activation and inhibition of protein tyrosine kinases (PTKs) and their interaction with other protein kinases on contractility were measured. ...
متن کاملQualitative changes in fetal trabecular meshwork fibers at the human iridocorneal angle
We examined a series of changes that occur in the trabecular meshwork fibers of human eyes during fetal development at 12-30 weeks of gestation. At 12 and 15 weeks, the uveal meshwork was stained black with silver impregnation (indicating the predominance of collagen types III and IV) in the endomysium of the ciliary muscle. At 20 weeks, in combination with Schlemm's canal, a dense fibrous tiss...
متن کاملRelaxation of trabecular meshwork and ciliary muscle by release of nitric oxide.
PURPOSE Recent evidence suggests that nitric oxide (NO) is a major messenger molecule regulating smooth muscle contractility. A role for NO in aqueous humor dynamics, and thus regulation of intraocular pressure, has been postulated. Recently, we described contractile properties of isolated bovine trabecular meshwork and ciliary muscle strips. To assess whether vasodilators contribute to the reg...
متن کاملOptimizing two-photon multiple fluorophore imaging of the human trabecular meshwork
PURPOSE Advances in two-photon (2P) deep tissue imaging provide powerful options for simultaneously viewing multiple fluorophores within tissues. We determined imaging parameters for optimally visualizing three fluorophores in the human trabecular meshwork (TM) to simultaneously detect broad-spectrum autofluorescence and multiple fluorophores through a limited number of emission filters. METH...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2016