Results of Culture Test at the Time of Removal of Metal Implants Used for Ankle Fracture Management

نویسندگان

  • Hyung-Jin Chung
  • Su-Young Bae
  • Jae-Ha Yu
چکیده

Purpose: The purpose of this study is to report the results of culture test at the time of removal of metal devices used for management of ankle fractures and for analysis of contributing factors. Materials and Methods: We reviewed medical records of 132 patients with lower tibia and ankle fracture who had their metal devices removed during the period from January 2010 to February 2014. Patients with clinical signs of infection were excluded. Culture test was performed by taking the granulation tissue around the metal device at the time of removal. We divided the subjects into two groups, culture positive and negative. We then performed a retrospective review of each medical record of multiple factors that might contribute to the culture results, including laboratory results, medical history, material and size of metal device, indwelling period, and whether or not it was open injury. Results: Among 132 cases, six were culture positive. Enterococcus was detected in two cases and the others were Staphylococcus. No significant difference in medical history of patients and laboratory results, including C-reactive protein level, was observed between the culture positive and negative group. Culture positive rate was 5.4% in titanium and 3.9% in stainless steel. In terms of metal size, culture positive rate was 5.1% in small plates, 6.7% in large plates, and culture negative in intramedullary nails. The average indwelling period of metal device was 61.5 weeks in the culture positive group, and 68.6 weeks in the negative group. Nine cases were open fractures and all were in the culture negative group. Conclusion: Whether or not the culture result was positive, there were no meaningful contributing factors. Presence of bacterium on the metal device could not be screened by any laboratory results or other factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between metal allergy and treatment outcomes after ankle fracture fixation.

PURPOSE To determine correlation between metal hypersensitivity and long-term foot and ankle function and pain after internal fixation using stainless steel implants. METHODS 60 men and 46 women (mean age, 47 years) who underwent internal fixation for ankle fractures completed a questionnaire 13 to 38 (mean, 26) months after surgery to assess their existing medical condition, history of metal...

متن کامل

Absorbable implants versus metal implants for the treatment of ankle fractures: A meta-analysis

This meta-analysis was performed to evaluate the efficiency and the safety of absorbable implants. Five major electronic databases (PubMed, Embase, Cochrane Library, SinoMed and Wanfang Data) were systematically searched for randomized controlled trials (RCTs) from their establishment to November 2012. Studies on absorbable implants and metal implants for ankle fractures were selected. The meta...

متن کامل

The Timeliness of Ankle Fracture Management from Presentation to Discharge; Our Experience from a District Eeneral Hospital

Introduction: Unstable ankle fractures are a common presentation and operative intervention has proven to improve patient outcomes. Each stage of patient management can have an impact on patient length of stay and clinical outcome. The aim of the present study is to assess how we manage the patient at each stage from their presentation right through to discharge, and if/how variation in practic...

متن کامل

بررسی نتایج خارج سازی ایمپلنت در بیماران مراجعه کننده به بیمارستان شهید صدوقی یزد از اردیبهشت ماه 1389 لغایت خرداد ماه1394

Introdution: Nowadays, the use of internal fixation in the field of orthopedics is increasing. On the other hand, there is no clear criteria at hand on removal of orthopedic implants, and there is disagreement among orthopedic surgeons on the necessity of routine removal of orthopedic implants in all patients after the healing of the fracture, and many surgeons take a personal approach towards ...

متن کامل

Kinetic study of heavy metal ions removal from aqueous solutions using activated pumice stone

Background: The presence of heavy metals in aquatic and terrestrial ecosystems causes harmful effects to living organisms in the environment. This research aimed to determine the potential of activated pumice stone (APS) as a sorbent for the removal of Cd, Cu, and Zn from wastewater. Methods: This research was conducted during 2013 on a laboratory scale. The study was performed using batch exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014