Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

نویسندگان

  • Y Liu
  • H Liu
  • Y Wang
  • G Wang
چکیده

To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan Feldkamp-type reconstruction in this unique geometry. In the numerical simulation with the Shepp-Logan phantom, representative images indicate that the proposed half-scan Feldkamp-type algorithm produces temporal resolution significantly superior to that with a single x-ray source cone-beam system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Analytic Cone-Beam Reconstruction for Multiaxial CT Acquisitions

A conventional 3rd generation Computed Tomography (CT) system with a single circular source trajectory is limited in terms of longitudinal scan coverage since extending the scan coverage beyond 40 mm results in significant cone-beam artifacts. A multiaxial CT acquisition is achieved by combining multiple sequential 3rd generation axial scans or by performing a single axial multisource CT scan w...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

CBCT within endodontics: an introduction

CBCT versus conventional CT Cone beam computed tomography (CBCT), which is also referred to as cone beam volumetric imaging (CBVI) and cone beam volumetric tomography (CBVT), is an extraoral radiographic method of producing three-dimensional digital radiographic information (Patel et al, 2009a; Patel, 2009; Miles, 2008; McNamara, Kapila, 2006; Horner, Drage, Brettle, 2008; Patel et al, 2007). I...

متن کامل

PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.

Current applications of helical cone-beam computed tomography (CT) involve primarily a constant pitch where the translating speed of the table and the rotation speed of the source-detector remain constant. However, situations do exist where it may be more desirable to use a helical scan with a variable translating speed of the table, leading a variable pitch. One of such applications could aris...

متن کامل

The Advantages of Volumetric Cone Beam Imaging for Orthopaedic Extremity Exams

Cone beam computed tomography (CBCT) is a variant of traditional computed tomography (CT) and was first described in the late 1970s. The main difference between the two approaches is the volume of the object that is imaged at one time. In traditional CT, a narrow slice of the patient is imaged with a “fan beam” of X-rays. For an extended volume of the anatomy via CT, the patient must be imaged ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2001