Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes
نویسندگان
چکیده
Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 μg/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).
منابع مشابه
Removal of Reactive Red 24 Dye by Clean Electrocoagulation Process using Iron and Aluminum Electrodes
In this research, the efficiency of electrocoagulation treatment process using iron and aluminum electrodes to treat synthetic wastewater containing Reactive Red 24 (RR 24) was studied. The effects of parameters such as current density, pH, type of electrolyte, initial dye concentration, electrolyte concentration, temperature, and inter electrode distance on dye removal efficiency were investig...
متن کاملمقایسه کارایی الکترودهای آلومینیومی و آهنی از لحاظ راندمان و هزینه در حذف فسفات، نیترات و COD از پساب یک واحد رختشویخانه به روش انعقاد الکتریکی
Background & Objectives: In this study, treatability of wastewater from a laundry unit was investigated by applying electrocoagulation method in which two pairs of aluminum and iron electrodes were utilized. Electrocoagulation is a noble treatment method suitable for different kinds of wastewater which has been given a considerable attentions by researchers recently. Applying direct current to ...
متن کاملAssessment of effective operational parameters on dyeing wastewater treatment by electrocoagulation process
A wide range of chemicals and dyes are being used in textile industry, and are often found in the wastewater produced. This study attempts to investigate the reduction of COD, TSS, and dye in effluents from the dyeing and washing unit of textile industry, using electrocoagulation process. The reactor is equipped with 10 iron electrodes, connected to a direct current (DC) source in a monopolar e...
متن کاملAssessment of effective operational parameters on dyeing wastewater treatment by electrocoagulation process
A wide range of chemicals and dyes are being used in textile industry, and are often found in the wastewater produced. This study attempts to investigate the reduction of COD, TSS, and dye in effluents from the dyeing and washing unit of textile industry, using electrocoagulation process. The reactor is equipped with 10 iron electrodes, connected to a direct current (DC) source in a monopolar e...
متن کاملRemoval of trace metal contaminants from potable water by electrocoagulation
This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed alu...
متن کامل