Reliability of assessing percentage of diffusion-perfusion mismatch.

نویسندگان

  • Shelagh B Coutts
  • Jessica E Simon
  • Anna I Tomanek
  • Philip A Barber
  • Jean Chan
  • Mark E Hudon
  • J Ross Mitchell
  • Richard Frayne
  • Michael Eliasziw
  • Alastair M Buchan
  • Andrew M Demchuk
چکیده

BACKGROUND AND PURPOSE Emergent neurovascular imaging holds promise in identifying new and optimum target populations for thrombolysis in stroke. Recent research has focused on patients with diffusion-weighted MRI (DWI)-perfusion-weighted MRI (PWI) mismatch as a marker of tissue at risk of infarction and a means to select the most suitable candidates for thrombolysis. The present study sought to estimate the reliability of assessing the percentage of DWI-PWI mismatch. METHODS Thirteen patients with acute strokes had DWI and PWI within 7 hours of symptom onset. Six raters independently created relative mean transit time (rMTT) maps and then compared them with DWI images to assess the percentage of mismatch (PWI>DWI) in 10% increments. The MR scans were reassessed by 4 raters, tracing around the lesions to calculate the volume percentage of mismatch. RESULTS Visual assessment had an interrater reliability of 0.68 (95% CI, 0.52 to 1.0; SEM=21.6%) and an intrarater reliability of 0.80 (95% CI, 0.47 to 1.0; SEM=16.9%). Hand-drawn assessment had an interrater reliability of 0.66 (95% CI, 0.45 to 1.0; SEM=26.2%) and an intrarater reliability of 0.94 (95% CI, 0.81 to 1.0; SEM=10.9%). CONCLUSIONS Results from the present study suggest that quantifying mismatch by the human eye is reproducible but not reliable among observers. This raises doubts about using mismatch for clinical decision making and clinical trial enrollment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of MR perfusion-weighted and diffusion-weighted imaging mismatch measurement methods.

BACKGROUND AND PURPOSE We investigated 2 methods of measuring MR imaging perfusion-diffusion mismatch to determine whether reliability is improved by direct measurement on a single, blended map. MATERIALS AND METHODS Image software was used for measurement of lesion volumes from diffusion-weighted images (DWI) and mean transit time (MTT) calculated from perfusion-weighted (PWI) images on 64 p...

متن کامل

Rapid assessment of perfusion-diffusion mismatch.

BACKGROUND AND PURPOSE For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. METHODS DWI and PWI were performed in 35 patients...

متن کامل

Severity of leukoaraiosis and susceptibility to infarct growth in acute stroke.

BACKGROUND AND PURPOSE Leukoaraiosis (LA) is associated with structural and functional vascular changes that may compromise tissue perfusion at the microvascular level. We hypothesized that the volume of LA correlated with the proportion of initially ischemic but eventually infarcted tissue in acute human stroke. METHODS We studied 61 consecutive patients with diffusion-weighted imaging-mean ...

متن کامل

EPITHET: Positive Result After Reanalysis Using Baseline Diffusion-Weighted Imaging/Perfusion-Weighted Imaging Co-Registration.

BACKGROUND AND PURPOSE the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET) was a prospective, randomized, double-blinded, placebo-controlled, phase II trial of alteplase between 3 and 6 hours after stroke onset. The primary outcome of infarct growth attenuation on MRI with alteplase in mismatch patients was negative when mismatch volumes were assessed volumetrically, without coregist...

متن کامل

Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.

BACKGROUND AND PURPOSE Perfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI). METHODS Acute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 34 7  شماره 

صفحات  -

تاریخ انتشار 2003