Evaluation of Global Surface-to-Volume Ratio of Rabbit Lung Using Hyperpolarized 129Xe Uptake Spectroscopy at 1.5T

نویسندگان

  • Y. Chang
  • J. F. Mata
  • T. Altes
  • J. P. Mugler
چکیده

Introduction Xe129 dissolves into tissue and binds hemoglobin in the lung (dissolved phase or DP) [1,2]. Study of the dynamics of DP Xe129 is enabled by its large chemical shift at about 200 ppm from the gas-phase signal as well as hyperpolarization [3,4]. The DP Xe129 signal can be further split into a peak of Xe dissolved into tissue and blood plasma (TP Xe) at approximately 197 ppm and another peak of Xe binding hemoglobin (B Xe) at 203--225 ppm (species dependent) [5,6]. The uptake dynamics of these two compartments of DP Xe contain valuable information about lung structure and function [7,8]. It is widely acknowledged that the short-time uptake behavior of the DP Xe surveys the local surface-to-volume ratio (SVR) [9-11] which is a key physiological parameter characterizing lung function and some lung diseases [12]. Since a tissue barrier is always present between the alveolar gas space and the capillary blood vessels [8], i.e., only tissue is in direct contact with the gas space in the lung, we hypothesize that the initial uptake of TP Xe alone can be used for SVR calculation. In this work we investigate the feasibility of measuring global SVR in the rabbit lung using a simple uptake model of the TP Xe at short delay times. Theory Let V denote the volume of total alveolar gas space in the lung. Let Sg be the amplitude of gas signal, then Sg = αV, where α is a ratio constant. For a short time td, the average depth of the tissue a Xe molecule travels into is (2DXe(t)td), where DXe(t) is the diffusivity of Xe in the lung tissue. If A is the total lung surface area, then the total amount of Xe in the tissue would be λA(2DXe(t)td), where λ is the Ostwald solubility of Xe in the lung tissue, and thus the tissue Xe signal St would be St = αλA(2DXe(t)td). Thus, St/Sg = (A/V)λ(2DXe(t)td) is linear with td, and the slope k is proportional to A/V or SVR via the relation k = (A/V)λ(2DXe(t)) (1). Methods The pulse sequence starts with three 900-μs Gaussian RF pulses at 200 ppm, separated by gradient spoilers, to ensure a complete saturation of the DP Xe. At a delay time td after the saturation a 90 ̊ RF at 200 ppm following a 1 ̊ RF at 0 ppm is applied and FID is collected 100 μs after the end of the RF pulse (32.55 Hz bandwidth/pixel, 1024 data points). 32 different values from 2 to 900 ms are used. Experiments were performed on a 1.5-T commercial whole-body imager (Avanto, Siemens Medical Solutions, Malvern, PA) using a custom-made transmit-receive birdcage RF coil (IGC Medical Advances, Milwaukee, WI). Two New Zealand rabbits (approximately 4 kg) were anesthetized with a mixture of Xylazine 5 mg/kg and Ketamine 50 mg/kg. The animals were then intubated and placed in the xenon RF coil. The rabbits were ventilated with 30 cc of isotopically enriched (85% Xe129) xenon gas, polarized to approximately 10-15% via spin exchange with an optically pumped rubidium vapor (Model IGI 9600Xe Xenon Polarizer, MITI, Durham, NC). The protocol was approved by our Institutional Animal Care and Use Committee. Details of data analysis can be found in [6]. In brief, a function consisting of the sum of two Lorentzians is used to fit the Fourier transformed data at 900-ms delay, where both TP and B Xe are evident in the DP spectrum, to obtain their heights, peak positions and line widths (full width at half maximum, or FWHM). Then the rest of the 31 spectra are fitted using the same function except with the peak positions fixed (~ 6 ppm apart). The signal amplitude of each compartment is calculated by integrating the associated Lorentzian. The fitting to the 900-ms delay DP spectrum is illustrated in Fig. 1. In order to compensate for signal loss before ADC, T2 of each signal source is estimated using the relation T2 = 1/(π FWHM). Signal amplitude is compensated by multiplying exp(t ́/T2) with its associated T2 and delay t ́ between center of RF and the beginning of ADC. All DP (TP + B) Xe signal amplitudes are divided by the corresponding gas amplitudes corrected for the 1 ̊ RF and are thus converted into the percentage of total gas in the lung. Because the time constant of B Xe is fairly long [6] and we are most interested in the short time behavior of uptake in this study, the B Xe is ignored and the TP Xe signals at short-delay times are fitted linearly with td. From the slope we can extract SVR using Eq. (1). Result The basic spectral information of the DP Xe is listed in the Table. TP signals of short-time delays from rabbit #1 are plotted against td in Fig. 2. A straight line going through the origin is used to fit data at delays less than 25 ms (√td < 0.16 √s), where data from both rabbits displayed good linearity. Using a previously estimated diffusion coefficient of dissolved Xe in tissue, DXe(t) = 3.3×10 cm/s [5], and λ = 0.078 at 37 C [13], we get SVR = 363 ± 24 cm. Discussion The result is in good agreement with histology studies [14]. However, the calculation of SVR relies heavily on the diffusion coefficient of Xe in the tissue DXe(t), which is tricky to measure and was only roughly estimated previously [5]. A more careful study of DXe(t) will improve the accuracy of SVR calculation. Another source of error comes from the small off-resonance excitation of the gas Xe from the exciting RF of DP Xe, which would slightly reduce the calculated SVR. Comparing with a similar work previously published [15], where the depolarization of the gas phase is plotted against td and slopes are compared with the histology studies, the current work excludes the exchange contribution from the B Xe at short delays and is able to calculate SVR directly from MR signals. Using only TP Xe signals prevented the calculation from being contaminated by B Xe signals that occur at early stage (likely due to thin tissue barrier). This approach can be potentially used to obtain SVR map of the lung when combined with imaging of the dissolved phase [8]. Conclusion In this work we demonstrated the feasibility of measuring global lung SVR using the uptake spectroscopy of only the tissue/plasma compartment of the dissolved-phase Xe, which may lead to accurate calculation of local SVR in the lung when imaging techniques are involved. References [1] Bifone A et al. PNAS 1996;93:12932. [2] Wolber J et al. PNAS 1999;96:3664. [3] Mugler III JP et al. MRM 1997; 37:809. [4] Ruppert K et al. NMR Biomed 2000;13:220. [5] Ruppert K et al. MRM 2004;51:676. [6] Chang Y et al. MRM submitted. [7] Mansson S et al. MRM 2003;50:1170. [8] Driehuys B et al. PNAS 2006;103:18278. [9] Ruppert K et al. MRM 2000;44:349. [10] Butler JP et al. J Phys: Condens Matter 2002;14:L297. [11] Patz S et al. Euro J Radiol 2007;64:335. [12] West JB. Pulmonary Pathophysiology. 1992. [13] Ladefoged J et al. Physiol Med Biol 1967;12:353. [14] Kovar J et al. J Appl Physiol 2002;93:629. [15] Cai J et al. ISMRM 2006; 863. Acknowledgements Work supported by NIH grant R01EB003202 and Siemens Medical Solutions. Fig. 1 Fitting of a 900-ms delay DP Xe spectrum to the sum of two Lorentzian shapes to separate the blood and tissue peaks and to determine their peak positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of human lung structure and physiology using hyperpolarized 129Xe.

PURPOSE To present in vivo, human validation of a previously proposed method to measure key pulmonary parameters related to lung microstructure and physiology. Some parameters, such as blood-air barrier thickness, cannot be measured readily by any other noninvasive modality. METHODS Healthy volunteers (n = 12) were studied in 1.5T and 3T whole body human scanners using hyperpolarized xenon. X...

متن کامل

Development of a hyperpolarized 129Xe system on 3T for the rat lungs.

MRI (magnetic resonance imaging) with 129Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized ...

متن کامل

Probing the alkyl ligands on silylated mesoporous MCM-41 using hyperpolarized 129Xe NMR spectroscopy.

Variable-temperature hyperpolarized (HP) 129Xe NMR spectroscopy has been employed to characterize surface properties of mesoporous MCM-41 modified by silylation treatment. The characteristic chemical shifts responsible for Xe-surface interactions exhibit strong correlations with both the surface coverage and chain length of the grafted alkylsilanes. Consequently, the deshielding medium contribu...

متن کامل

Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans

BACKGROUND One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS Here we exploit the solubility, hig...

متن کامل

Cell-compatible, integrin-targeted cryptophane-129Xe NMR biosensors.

Peptide-modified cryptophane enables sensitive detection of protein analytes using hyperpolarized 129Xe NMR spectroscopy. Here we report improved targeting and delivery of cryptophane to cells expressing αvβ3 integrin receptor, which is overexpressed in many human cancers. Cryptophane was functionalized with cyclic RGDyK peptide and Alexa Fluor 488 dye, and cellular internalization was monitore...

متن کامل

Hyperpolarized 129Xe NMR investigation of multifunctional organic/inorganic hybrid mesoporous silica materials.

An extensive study has been made on a series of multifunctional mesoporous silica materials, prepared by introducing two different organoalkoxysilanes, namely 3-[2-(2-aminoethylamino)ethylamino]propyltrimethoxysilane (AEPTMS) and 3-cyanopropyltriethoxysilane (CPTES) during the base-catalyzed condensation of tetraethoxysilane (TEOS), using the variable-temperature (VT) hyperpolarized (HP) 129Xe ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009