Device-associated infections in a Colombian neonatal intensive care unit.

نویسندگان

  • Germán A Contreras-Cuellar
  • Aura L Leal-Castro
  • Reinaldo Prieto
  • Alba L Carvajal-Hermida
چکیده

OBJECTIVE The present study was aimed at determining device-associated infection rates, device use rates and the microbiologic profile of nosocomial infections in a tertiary neonatal intensive care unit (ICU) in Bogotá, Colombia. METHODS Prospective nosocomial infection surveillance was implemented in a neonatal intensive care unit for 11 months in line with the High Risk Nursery component of the Colombian Nosocomial Infection Surveillance programme. Patient-days, length of stay, device use rates and device-associated nosocomial infection rates were calculated. RESULTS 1 998 device days were observed among 2 890 patient days during the 11 months' surveillance. Central venous catheter-related bloodstream infection was the most common device-associated infection for all birth-weight categories. 69,2 % and 100 % of all coagulase negative staphylococci and Staphylococcus aureus infections were methicillin resistant strains and all gram negative rods were susceptible to third generation cephalosporins, carbapenems, ciprofloxacin and piperacillin-tazobactam. Device-associated infection and device use rates in the ICU were higher than Colombian Nosocomial Infection Surveillance reports for October 2004 and reports from Colombia and other Latin-American countries. CONCLUSIONS This surveillance identified blood-stream infection as being the most common infection in the ICU in question. Efforts should thus be directed at establishing suitable infection-control practices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of device-associated infections in intensive care units

Background: Health care associated infections (HAIs) are a class of infections that infect patients during hospital admissions and receive medical services. These infections occurs within 48 to 72 hours of admission and up to 6 weeks after discharge. Surveillance of device-associated infections (DAIs) in intensive care units (ICUs) is substantial in planning healthcare strategies. This study wa...

متن کامل

عفونت‌های بیمارستانی و عوامل باکتریایی آنها: بخش مراقبت‌های ویژه نوزادان بیمارستان دانشگاهی قائم (عج) مشهد

Background: Nosocomial infections increase patients' morbidity, mortality and length of hospital stay especially in neonatal intensive care units (NICUs) and have become a matter of major concern. Controlling and preventing nosocomial infections need enough information about epidemiology of these infections. This study aims at estimating the incidence rate and the most frequent bacteria which c...

متن کامل

The Study of Nosocomial Infections in Neonatal Intensive Care Unit, A prospective study in Northwest Iran

Background: Nosocomial infections are an important cause of mortality in neonatal intensive care units (NICUs). Therefore, in this study, the incidence and prevalence of nosocomial infections were determined in NICUs of the three largest neonatal centers in northwest Iran, and the causative bacteria were identified in order to provide potential solutions to control the infections in these hospi...

متن کامل

A Rare Case Report of a Collodion Baby with Severe Hypernatremia

Background: Collodion baby is a rare condition (i.e., 1:300000 birth), which is referred to a neonate covered with a tight and shiny membrane desquamating within two weeks. This condition takes place as a result of the epidermal cornification disorder. Given the impairment of the skin barrier function, these neonates are at the risk of several complications, including hypernatremic dehydration,...

متن کامل

Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista de salud publica

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2007