Assessment of drinking water quality using indicator bacteria and bacteriophages.
نویسندگان
چکیده
Bacterial indicators and bacteriophages suggested as potential indicators of water quality were determined by public laboratories in water from springs, household water wells, and rural and metropolitan water supplies in north-eastern Spain. Indicator bacteria were detected more frequently than bacteriophages in springs, household water wells and rural water supplies. In contrast, positive bacteriophage detections were more numerous than those of bacteria in metropolitan water supplies. Most of the metropolitan water supply samples containing indicators had concentrations of chlorine below 0.1 mg l(-1), their indicator loads resembling more closely those of rural water supplies than any other samples taken from metropolitan water supplies. The number of samples from metropolitan water supplies containing more than 0.1 mg l(-1) of chlorine that contained phages clearly outnumbered those containing indicator bacteria. Some association was observed between rainfall and the presence of indicators. Sediments from service reservoirs and water from dead ends in the distribution network of one of the metropolitan water supplies were also tested. Bacterial indicators and phages were detected in a higher percentage than in samples of tap water from the same network. Additionally, indicator bacteria were detected more frequently than bacteriophages in sediments of service reservoirs and water from dead end samples. We conclude that naturally occurring indicator bacteria and bacteriophages respond differently to chlorination and behave differently in drinking water distribution networks. Moreover, this study has shown that testing for the three groups of phages in routine laboratories is easy to implement and feasible without the requirement for additional material resources for the laboratories.
منابع مشابه
A Survey on Drinking Water Contamination to Indicator Bacteria in Dairy Farms of Mashhad Suburb
BACKGROUND: Microbial quality of drinking water is very important in animal health. OBJECTIVES: The present survey was conducted to evaluate the microbial quality of cows' drinking water in dairy farms in Mashhad suburb, Iran, to find out defects in this field. METHODS: Water samples were taken from 30 farms and 4 sites including: Water tanks, inlet and outlet of bovine drinking troughs and c...
متن کاملFungi Occurrence Assessment in Drinking Water Distribution Systems and Its Relationship with Fecal Indicator Bacteria
Introduction: As recommended by World Health Organization, consumption of the fungal contaminated water does not cause to serious infection, but may lead to healthy or aesthetic problems. The aim of this research was to assess the occurrence of fungi in water and its relationship with fecal indicator bacteria. Materials and Methods: 110 water samples were collected from different location of w...
متن کاملتعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN
Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...
متن کاملRapid Monitoring of Indicator Coliforms in Drinking Water by an Enzymatic Assay
Coliform group has been extensively used as an indicator of drinking water quality and historically led to the public health protection concept. Multiple tube fermentation technique has been currently used for assessment of the microbial quality of drinking water. This method, however, has limitations. Enzymatic assay constitute an alternative approach for detecting indicator bacteria, namely t...
متن کاملباکتریهای هتروتروف در آب آشامیدنی شهر تبریز
Background and Aim: Recently the use of heterotrophic plate count (HPC) has received much attention as a supplementary indicator of the MPN test in water quality control. The US Environmental Protection Agency (USEPA) has declared 500 cfu/mL as the maximum acceptable level for heterotrophic bacteria in distribution networks. Currently the HPC determination is not among the routine control items...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of water and health
دوره 2 3 شماره
صفحات -
تاریخ انتشار 2004