Computer imaging software for profile photograph analysis.

نویسندگان

  • Travis T Tollefson
  • Jonathan M Sykes
چکیده

OBJECTIVES To describe a novel calibration technique for photographs of different sizes and to test a new method of chin evaluation in relation to established analysis measurements. DESIGN A photograph analysis and medical record review of 14 patients who underwent combined rhinoplasty and chin correction at an academic center. Patients undergoing concurrent orthognathic surgery, rhytidectomy, or submental liposuction were excluded. Preoperative and postoperative digital photographs were analyzed using computer imaging software with a new method, the soft tissue porion to pogonion distance, and with established measurements, including the cervicomental angle, the mentocervical angle, and the facial convexity angle. RESULTS The porion to pogonion distance consistently increased after the chin correction procedure (more in the osseous group). All photograph angle measurements changed toward the established normal range postoperatively. CONCLUSIONS Surgery for facial disharmony requires artistic judgment and objective evaluation. Although 3-dimensional video analysis of the face seems promising, its clinical use is limited by cost. For surgeons who use computer imaging software, analysis of profile photographs is the most valuable tool. Even when preoperative and postoperative photographs are of different sizes, relative distance comparisons are possible with a new calibration technique using the constant facial landmarks, the porion and the pupil. The porion-pogonion distance is a simple reproducible measurement that can be used along with established soft tissue measurements as a guide for profile facial analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A CAD System Framework for the Automatic Diagnosis and Annotation of Histological and Bone Marrow Images

Due to ever increasing of medical images data in the world’s medical centers and recent developments in hardware and technology of medical imaging, necessity of medical data software analysis is needed. Equipping medical science with intelligent tools in diagnosis and treatment of illnesses has resulted in reduction of physicians’ errors and physical and financial damages. In this article we pr...

متن کامل

Image-Based Lighting Design

In this paper, we present a lighting design framework for neardiffuse real objects, starting from a set of prerecorded photographs of an object under various lighting conditions. Light sources are placed at fixed positions around an object, for which the intensities are to be determined. Using existing digital imaging software, the lighting designer paints the desired illumination distribution ...

متن کامل

Computerize classification of Benign and malignant thyroid nodules by ultrasound imaging

Introduction: Early detection and treatment of thyroid nodules increase the cure rate and provide optimal treatment. Ultrasound is the chosen imaging technique for assessment of thyroid nodules. Confirmation of the diagnosis usually demands repeated fine needle aspiration biopsy (FNAB). So, current management, has morbidity and non zero mortality. The goal of the present study ...

متن کامل

Software Tools for the Analysis of Functional Magnetic Resonance Imaging

Functional magnetic resonance imaging (fMRI) has become the most popular method for imaging of brain functions. Currently, there is a large variety of software packages for the analysis of fMRI data, each providing many features for users. Since there is no single package that can provide all the necessary analyses for the fMRI data, it is helpful to know the features of each software package. ...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of facial plastic surgery

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2007