Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance.

نویسندگان

  • Beatrice M Stefanescu
  • T Michael O'Shea
  • Fran Haury
  • Waldemar A Carlo
  • James C Slaughter
چکیده

BACKGROUND The OxiMax N-600x containing SatSeconds alarm management software was designed to assist clinicians in discriminating nuisance alarms from those that are clinically relevant. Instead of sounding an alarm the moment the oxygen saturation reading violates the upper or lower limit settings, a magnitude and duration of tolerance can be set. The primary objective was to study the proportion of nuisance alarms relative to the proportion of clinically relevant alarms being filtered under 4 different SatSeconds alarm settings (ie, 10, 25, 50, and 100) in the neonatal intensive care environment. METHODS This is an observational prospective study of 50 infants cared for in 3 large neonatal ICUs. Infants were monitored for 4 continuous h each by a study observer with the study monitor, in addition to standard multiparameter monitors. The performance of the SatSeconds alarm was compared with nursing intervention. RESULTS The area under the receiver operating characteristic curve (95% CI) for SatSeconds alarm settings when compared with nursing intervention were as follows: 0.61 (0.57-0.66) when the SatSeconds alarm setting was off, 0.63 (0.59-0.68) for the 10 SatSeconds alarm setting, 0.64 (0.59-0.69) for the 25 SatSeconds alarm setting, 0.64 (0.59-0.69) for the 50 SatSeconds alarm setting, and 0.63 (0.58-0.68) for the 100 SatSeconds alarm setting, respectively. CONCLUSIONS The SatSeconds feature of the OxiMax N-600x pulse oximeter reduced some nuisance alarms; however, its specificity to nurse-identified desaturation events does not significantly improve with lengthening SatSeconds alarm settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neonatal and pediatric pulse oximetry.

The pulse oximeter has become a vital instrument in the care of infants and children with cardiopulmonary disease. Recent advances in pulse oximetry technology have improved some aspects of pulse oximeter performance. However, the reliability, accuracy, and clinical utility of pulse oximetry remain problematic in some types of patients under certain conditions. Improved signal processing techno...

متن کامل

Retrospective analysis of pulse oximeter alarm settings in an intensive care unit patient population

BACKGROUND The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient vari...

متن کامل

[Pulse oximetry in neonatal care in 2005. A comprehensive state of the art review].

INTRODUCTION Oxygen saturation monitors or pulse oximeters (SpO2) were entered into practice in the 1980s not only without randomized trials but also, and probably more importantly, without education of neonatal bedside care providers around the world (i. e.: nursing staff, respiratory therapists and also physicians). Education about some known physiological principles, such as the changing rel...

متن کامل

A pilot randomized controlled trial of EKG for neonatal resuscitation

BACKGROUND The seventh edition of the American Academy of Pediatrics Neonatal Resuscitation Program recommends the use of a cardiac monitor in infants that need resuscitation. Previous trials have shown that EKG heart rate is available before pulse rate from a pulse oximeter. To date no trial has looked at how the availability of electrocardiogram (EKG) affects clinical interventions in the del...

متن کامل

آگاهی کارکنان درمانی بخش‌های ویژه نوزادان و کودکان درباره پالس‌اکسی‌متری

Background & Aim: Pulse Oximeter monitoring technology has become so common in intensive health care settings over the last decade that blood oxygen level is now considered as the fifth vital sign. However, it seems that medical and nursing staffs are not specially educated to operate with the devices. The aim of the study was to investigate the knowledge of medical assistants (residents), nurs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 61 1  شماره 

صفحات  -

تاریخ انتشار 2016