Non-invasive assessment of failure torque in rat bones with simulated lytic lesions using computed tomography based structural rigidity analysis.
نویسندگان
چکیده
This study applies CT-based structural rigidity analysis (CTRA) to assess failure torque of rat femurs with simulated lytic defects at different locations (proximal and distal femur) and diameters (25% and 50% of the cross-section at the site), and compared the results to those obtained from mechanical testing. Moreover, it aims to compare the correlation coefficients between CTRA-based failure torque and DXA-based aBMD versus actual failure torque. Twenty rats were randomly assigned to four equal groups of different simulated lesions based on size and location. Femurs from each animal underwent micro-computed tomography to assess three-dimensional micro-structural data, torsional rigidity using structural rigidity analysis and dual energy X-ray absorptiometry to assess bone mineral density. Following imaging, all specimens were subjected to torsion. Failure torque predicted from CT-derived structural rigidity measurements was better correlated with mechanically derived failure torque [R(2)=0.85] than was aBMD from DXA [R(2)=0.32]. In summary, the results of this study suggest that computed tomography based structural rigidity analysis can be used to accurately and quantitatively measure the mechanical failure torque of bones with osteolytic lesions in an experimental rat model. Structural rigidity analysis can provide more accurate predictions on maximal torque to mechanical failure than dual energy X-ray absorptiometry based on bone mineral density.
منابع مشابه
Finite element analysis and CT-based structural rigidity analysis to assess failure load in bones with simulated lytic defects.
There is an urgent need to improve the prediction of fracture risk for cancer patients with bone metastases. Pathological fractures that result from these tumors frequently occur in the femur. It is extremely difficult to determine the fracture risk even for experienced physicians. Although evolving, fracture risk assessment is still based on inaccurate predictors estimated from previous retros...
متن کاملFinite element analysis and computed tomography based structural rigidity analysis of rat tibia with simulated lytic defects.
Finite element analysis (FEA), CT based structural rigidity analysis (CTRA) and mechanical testing is performed to assess the compressive failure load of rat tibia with simulated lytic defects. Twenty rat tibia were randomly assigned to four equal groups (n=5). Three of the groups included a simulated defect at various locations: anterior bone surface (Group 1), posterior bone surface (Group 2)...
متن کاملCurved Beam Computed Tomography based Structural Rigidity Analysis of Bones with Simulated Lytic Defect: A Comparative Study with Finite Element Analysis
In this paper, a CT based structural rigidity analysis (CTRA) method that incorporates bone intrinsic local curvature is introduced to assess the compressive failure load of human femur with simulated lytic defects. The proposed CTRA is based on a three dimensional curved beam theory to obtain critical stresses within the human femur model. To test the proposed method, ten human cadaveric femur...
متن کاملAn improved method to assess torsional properties of rodent long bones.
Torsion is an important testing modality commonly used to calculate structural properties of long bones. However, the effects of size and geometry must be excluded from the overall structural response in order to compare material properties of bones of different size, age and species. We have developed a new method to analyze torsional properties of bones using actual cross-sectional informatio...
متن کاملAssessment of axial bone rigidity in rats with metabolic diseases using CT-based structural rigidity analysis
OBJECTIVES This study aims to assess the correlation of CT-based structural rigidity analysis with mechanically determined axial rigidity in normal and metabolically diseased rat bone. METHODS A total of 30 rats were divided equally into normal, ovariectomized, and partially nephrectomized groups. Cortical and trabecular bone segments from each animal underwent micro-CT to assess their averag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2011