Assessment of coronary artery disease using 3.0T magnetic resonance coronary angiography: a national multicenter trial
نویسندگان
چکیده
Background 3.0T contrast enhanced whole-heart coronary magnetic resonance angiography (MRA) is a promising method for noninvasive, radiation-free detection and exclusion of obstructive coronary artery disease (CAD); however, the accuracy of this approach has not been determined in a multicenter trial. Methods An ECG-triggered, navigator-gated, inversion-recovery prepared, segmented gradient-echo sequence was used for image acquisition in 272 patients with suspected CAD at 8 hospitals. The accuracy of coronary MRA for detecting a 50% diameter reduction was determined using X-ray coronary angiography as the reference method. Using an
منابع مشابه
Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial.
OBJECTIVES This national multicenter study determined the diagnostic performance of 1.5-T whole-heart coronary magnetic resonance angiography (MRA) in patients with suspected coronary artery disease (CAD). BACKGROUND Whole-heart coronary MRA using steady-state free precession allows noninvasive detection of CAD without the administration of contrast medium. However, the accuracy of this appro...
متن کامل3.0T whole-heart coronary magnetic resonance angiography performed with 32-channel cardiac coils: a single-center experience.
BACKGROUND Whole-heart coronary magnetic resonance angiography (MRA) is a promising method for noninvasive, radiation-free detection and exclusion of obstructive coronary artery disease; however, the required imaging time and robustness of the technique are not yet satisfactory. We evaluated the value of whole-heart coronary MRA at 3.0T using a 32-channel cardiac coil, which reduces image-acqui...
متن کاملAutomated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T
Background Contrast-enhanced whole heart coronary Magnetic Resonance Angiography (MRA) at 3.0 Tesla (T) allows noninvasive detection of obstructive stenoses. Automated vessel segmentation and tracking of centerlines is important for quantitative measurement of stenosis, but remains challenging for coronary MRA. We aimed to develop and validate automated coronary artery segmentation from contras...
متن کاملRelationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction
Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...
متن کاملCorrelation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study
Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...
متن کامل