Analysis of heart rate variability in individuals subjected to different positive end expiratory pressure levels using expiratory positive airway pressure
نویسندگان
چکیده
INTRODUCTION The increase in the number of studies has led to greater security in the application of this method and the determination of its effectiveness in adults.. The purpose of the present study was to evaluate heart rate variability in healthy individuals submitted to different levels of positive expiratory pressure using an expiratory positive airway pressure (EPAP) device. MATERIAL AND METHODS The study involved 27 healthy male individuals ranging in age from 20 to 35 years. Patient histories were taken and the subjects were submitted to a physical examination. The volunteers were monitored using the Polar 810s(®) and submitted to the EPAP experiment. Analyses were performed on variables of the frequency domain. Sympathetic and parasympathetic bands and their relationship with sympathovagal response were also analyzed. RESULTS The mean value of this variable was 526.89 (55.50) ms(2) in the first period, 2811.0 (721.10) ms(2) in the fourth period and 726.52 (123.41) ms(2) in the fifth period. Regarding the parasympathetic area, significant differences were detected when Periods 1 and 5 (no load) were compared with periods in which the individuals were subjected to the use of the therapy. Sympathetic and parasympathetic areas together, a significant difference was detected regarding the sympathetic/parasympathetic ratio in the comparison between Periods 1 and 4 (p < 0.01) as well as Periods 2 and 4 (p < 0.05). CONCLUSIONS The findings of the present study suggest that the therapeutic use of EPAP significantly alters the parameters of heart rate variability in the frequency domain, highlighting the importance of monitoring and care during the practice of EPAP.
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملThe prophylactic effect of different levels of positive end-expiratory pressure on the incidence rate of atelectasis after cardiac surgery: A Randomized Controlled Trial
Background: The use of positive end-expiratory pressure (PEEP) can have an important role as one of the ways to prevent and treat atelectasis, but it seems that there is still no consensus about its beneficial level. The aim of this study was to determine the effect of different levels of PEEP on the incidence of atelectasis after heart surgery. Methods: This is...
متن کاملPositive Expiratory Pressure (PEP) versus Conventional Chest Physiotherapy in Pediatric Patients with Acute Exacerbation of Cystic Fibrosis
Background Pulmonary involvement is the main cause of mortality in cystic fibrosis (CF). Airway clearance techniques are non-pharmacological complement options for CF patients. The aim of this study was to evaluate the short-term outcome of airway cleaning treatment in patients with cystic fibrosis in a children's hospital. Materials and Methods This clinical trial study conducted on 40 CF pati...
متن کاملEffect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates
Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...
متن کاملInfluence of ventilation strategies on survival in severe controlled hemorrhagic shock.
OBJECTIVE To investigate the effect of different ventilation settings on hemodynamic stability in severe controlled hemorrhagic shock. DESIGN Prospective, randomized, controlled animal study. SETTING Research laboratory in a university hospital. SUBJECTS Approximately 35-45 kg domestic pigs. INTERVENTIONS Twenty-four domestic pigs were bled 45 mL/kg (estimated 65% of their calculated bl...
متن کامل