Validation of a new automated renin assay.

نویسندگان

  • René A de Bruin
  • Angelique Bouhuizen
  • Sven Diederich
  • Frank H Perschel
  • Frans Boomsma
  • Jaap Deinum
چکیده

BACKGROUND Measurement of plasma renin is important for the treatment of patients with congenital adrenal hyperplasia (CAH) and in the evaluation of patients with suspected hyperaldosteronism. Immunologic assays for plasma renin offer easier implementation and standardization than enzyme-kinetic assays for plasma renin activity, but their sensitivity and specificity have been questioned. We studied a renin immunochemiluminescence assay on an automated platform. METHODS Renin was measured by an enzymatic assay, by IRMA, and by the new Nichols Advantage Specialty System immunochemiluminometric assay (ICMA), in plasmas from unselected individuals from our outpatient departments and in samples from patients with selected diagnoses. RESULTS The detection limit in the ICMA was 0.1 mU/L. The recovery was >90%, and the imprecision (CV) was generally <9%. Mean (SD) concentrations measured by ICMA were 32 (21)% lower than those measured by IRMA. Renin concentrations as measured by ICMA were identical in serum and EDTA-, heparin-, and citrate-anticoagulated plasmas. Prolonged incubation of whole blood at room temperature before centrifugation did not affect renin concentrations. The central 95% interval for 80 healthy adults was 6-85.5 mU/L. Plasma renin as assessed by ICMA in patients with primary hyperaldosteronism was <0.2 mU/L. CONCLUSIONS The performance characteristics of the new renin ICMA allow its use for patients with CAH and for the diagnosis of mineralocorticoid hypertension. In view of the variability of renin concentrations, use for other forms of hypertension or physiologic research calls for the development of uniform sampling protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive Modeling of Phenylpiperazine Derivatives for Renin Inhibition.

The renin–angiotensin–aldosterone system is the well established endocrine system having significant role in preserving hemodynamic stability. Renin is secreted from the juxtaglomerular cells of the kidney. Phenylpiperazine derivatives have been reported as human renin inhibitor. To perform predictive QSAR modeling for 27 phenylpiperazine derivatives as renin enzyme inhibitors. The IC50 values ...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Clinical validation of renin monoclonal antibody-based sandwich assays of renin and prorenin, and use of renin inhibitor to enhance prorenin immunoreactivity.

Newly developed IRMAs to measure the plasma concentrations of renin and prorenin were validated for clinical use and compared with a classical enzyme kinetic assay. The IRMAs involve two monoclonal antibodies, one that reacts equally well with renin and prorenin and one that recognizes renin well but prorenin only minimally. Prorenin reactivity with the second antibody was enhanced by adding th...

متن کامل

A screening procedure for primary aldosteronism based on the Diasorin Liaison automated chemiluminescent immunoassay for direct renin.

BACKGROUND Primary aldosteronism (PA), the most common secondary cause of hypertension, can be screened for using the aldosterone/renin ratio. This ratio is raised in PA and its accuracy depends on the ability to measure plasma renin at extremely low concentrations. METHODS We compared two different procedures for assessing plasma renin. The conventional method, which measures plasma renin ac...

متن کامل

Screening for primary aldosteronism using the newly developed IDS-iSYS® automated assay system

BACKGROUND The recommended approach to screening for primary aldosteronism (PA) in at-risk populations is to determine the ratio of aldosterone concentration (serum (SAC)/plasma (PAC)) to renin measured in plasma as activity (PRA) or concentration (DRC). However, lack of assay standardisation mandates the need for method-specific decision thresholds and clinical validation in the local populati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 11  شماره 

صفحات  -

تاریخ انتشار 2004