Interpretation of solute retention of some monovalent inorganic anions in anion-exchange chromatography using a dicarboxylic Acid as an eluent.
نویسندگان
چکیده
In single-column anion-exchange chromatography, the retention volume of some monovalent inorganic anions (Cl(-), Br(-), NO(3)(-), NCS(-) and NO(2)(-)) were observed as a function of the pH of a mobile phase at a fixed concentration of 2-phenylmalonic acid or 1,4-benzenediacetic acid used as an eluent. The experimental retention volume of such an anion was decreased with an increase in the pH of a mobile phase, and was able to be described by the following equation taking account of anion-exchange equilibria of a sample anion with a hydrogen dicarboxylate ion (HE(-)) and with a dicarboxylate ion (E(2-)): alpha(1s)/V(R)'[HE(-)] = 1/m(T)wK(ex1) + (2K(a2)/m(T)w(2)K(ex2))(V(R)'/alpha(1s)[H(+)]), where V(R)', m(T), w, K(a2), K(ex1) and K(ex2) are the adjusted retention volume of a given sample anion, the capacity for the anion-exchange of column packings and the weight of column packings packed into a separating column, the second acid-dissociation constant of the dicarboxylic acid used as an eluent, and equilibrium constants for the anion exchange of a sample anion with a monovalent hydrogen dicarboxylate ion and with a divalent dicarboxylate ion, respectively. The term alpha(1s), defined as K(as)/([H(+)] + K(as)), where K(as) is the acid-dissociation constant of HX, is the mole fraction of a sample anion, X(-), and is equal to 1 when using a strong acid anion as a sample anion.
منابع مشابه
Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.
An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...
متن کاملSeparation of inorganic anions by liquid chromatography with crown ether as eluent additive.
Inorganic anions were separated on a reversed-phase stationary phase dynamically modified with crown ether as a selector in capillary ion chromatography. The eluent contained crown ether, acetonitrile and a salt. Free and cation-trapped crown ether molecules in the eluent were adsorbed on a hydrophobic stationary phase such as triacontyl-functionalized silica (C30). The eluent cations trappe...
متن کاملFast ion chromatography of inorganic anions and cations on a lysine bonded porous silica monolith.
A 0.46 cm x 10.0 cm silica monolith column was modified through the in situ covalent attachment of lysine (2,6-diaminohexanoic acid) groups. Due to the zwitterionic nature of the resultant stationary phase, the modified monolithic column contained both cation and anion exchange capacity. In the case of cation exchange, the capacity was found to be relatively low at between 5 and 6.5 micromoles ...
متن کاملSeparation of inorganic anions on a chemically bonded 18-crown-6 ether stationary phase in capillary ion chromatography.
Inorganic anions were separated on a chemically bonded 18-crown-6 ether (18C6E) stationary phase in capillary ion chromatography. In this study 18C6E groups were chemically bonded on silica gel via reaction with 3-glycidyloxypropyltrimethoxysilane, followed by reaction with 2-aminomethyl-18C6E. Analyte anions were separated in the ion-exchange mode based on the fact that the eluent cation was t...
متن کاملDetermination of trace anions in high-nitrate matrices by ion chromatography.
An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2006