Evaluation of a fiber optic glove for semi-automated goniometric measurements.
نویسندگان
چکیده
Normal subjects were used to evaluate a fiber optic instrumented glove for semi-automated goniometric measurement. The glove electronically records and transmits hand and finger position to a host computer by measuring the amount of joint flexion. The glove was put through a series of range-of-motion (ROM) tests with five subjects. Metacarpal (MP) and proximal interphalangeal (PIP) joint angles of the five digits were compared during repetitive standardized motions to evaluate the glove's repeatability. The results showed an overall error of 5.6 degrees, as compared to an error of between 5 and 8 degrees with manual measurement. Additional tests were done to determine factors such as fit, grip force, and wrist motion that may contribute to the overall error. The glove should have applicability to some aspects of hand evaluation as a semi-automated goniometric measurement device.
منابع مشابه
Fiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)
The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...
متن کاملValidation of Goniometric Method in the Assessment of Lordosis by Radiographic Analysis
Background & Aims: Cervical spine is prone to various abnormalities and sport injuries. There is still no non-aggressive measurement instrument with high reliability for easy and rapid assessment of cervical spine secondary complications. The aim of this research was to investigate the validity of goniometric method for cervical lordosis measurement through radiography. Method: In this study, 1...
متن کاملSemi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis
Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT. We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). ...
متن کاملAutomated manufacturing systems for high-volume packaging of fiber-optic components
ponents based on wavelength-division multiplexing (WDM) technology is increasing rapidly. But many sales opportunities are missed because manufacturers can’t assemble these devices fast enough. This has led to a worldwide shortage in commercially available fiber-optic WDM components. The problem is mainly due to a lack of fully automated production lines in the optoelectronic device manufacturi...
متن کاملA fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 27 4 شماره
صفحات -
تاریخ انتشار 1990