Spline-based procedures for dose-finding studies with active control
نویسندگان
چکیده
In a dose-finding study with an active control, several doses of a new drug are compared with an established drug (the so-called active control). One goal of such studies is to characterize the dose-response relationship and to find the smallest target dose concentration d(*), which leads to the same efficacy as the active control. For this purpose, the intersection point of the mean dose-response function with the expected efficacy of the active control has to be estimated. The focus of this paper is a cubic spline-based method for deriving an estimator of the target dose without assuming a specific dose-response function. Furthermore, the construction of a spline-based bootstrap CI is described. Estimator and CI are compared with other flexible and parametric methods such as linear spline interpolation as well as maximum likelihood regression in simulation studies motivated by a real clinical trial. Also, design considerations for the cubic spline approach with focus on bias minimization are presented. Although the spline-based point estimator can be biased, designs can be chosen to minimize and reasonably limit the maximum absolute bias. Furthermore, the coverage probability of the cubic spline approach is satisfactory, especially for bias minimal designs.
منابع مشابه
Calculations of Linac Photon Dose Distributions in Homogeneous Phantom Using Spline
Introduction Relative dose computation is a necessary step in radiation treatment planning. Therefore, finding an approach that is both fast and accurate seems to be necessary. The purpose of this work was to investigate the feasibility of natural cubic spline to reconstruct dose maps for linear accelerator radiation treatment fields in comparison with those of the simulation. Materials and Met...
متن کاملDesigning dose finding studies with an active control for exponential families.
In a recent paper Dette et al. (2014) introduced optimal design problems for dose finding studies with an active control. These authors concentrated on regression models with normal distributed errors (with known variance) and the problem of determining optimal designs for estimating the smallest dose, which achieves the same treatment effect as the active control. This paper discusses the prob...
متن کاملOptimal designs for dose finding studies with an active control
Dose finding studies often compare several doses of a new compound with a marketed standard treatment as an active control. In the past, however, research has focused mostly on experimental designs for placebo-controlled dose finding studies. To the best of our knowledge, optimal designs for dose finding studies with an active control have not been considered so far. As the statistical analysis...
متن کاملPoint and Interval Estimators of the Target Dose in Clinical Dose-Finding Studies with Active Control
In a clinical dose finding study with active control a new drug with several dose levels is compared with an active comparator drug. The main focus of such studies often lies on the estimation of a target dose that leads to the same efficacy as the control. This article investigates the finite sample properties of the maximum likelihood estimation of the target dose and compares several approac...
متن کاملActive Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...
متن کامل