Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water.
نویسندگان
چکیده
Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (C(TWA)) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the uptake rate constant (k(u)) in TECAM was less sensitive to temperature variation than the SPMD and Chemcatcher. The k(u) in TECAM was sensitive to even a slight change of the flow rate, which required the field calibration using performance reference compounds (PRCs). To estimate C(TWA) by TECAM, both empirical model and WBL model were compared in laboratory conditions, and only small differences were observed between the predicted and measured k(u). Field validation was conducted to test the sampler performance alongside spot sampling. A good agreement of water concentration was obtained by the two sampling techniques.
منابع مشابه
Removal of persistent organic pollutants from micro-polluted drinking water by triolein embedded absorbent.
A new biomimetic absorbent, cellulose acetate (CA) embedded with triolein (CA-triolein), was prepared and applied for the removal of persistent organic pollutants (POPs) from micro-polluted aqueous solution. The comparison of CA-triolein, CA and granular activated carbon (GAC) for dieldrin removal was investigated. Results showed that CA-triolein absorbent gave a lowest residual concentration a...
متن کاملPassive sampling of perfluorinated chemicals in water: in-situ calibration.
Perfluorinated chemicals (PFCs) have been recognised as environmental pollutants that require monitoring. A modified polar organic chemical integrative sampler (POCIS) is able to quantify aqueous PFCs. However, with varying external water velocity, PFC sampling rates (Rs) may change, affecting accuracy of derived water concentrations. To facilitate field deployment of this sampler, two methods ...
متن کاملCalibration and response of an agarose gel based passive sampler to record short pulses of aquatic organic pollutants.
A passive sampler inspired from previous devices was developed for the integrative sampling of a broad range of contaminants in the water column. Our primary objective was to improve the performance of the device to provide accurate and averaged pollutant water concentrations. For this purpose, an agarose diffusive gel was used as the boundary layer that drives the analyte uptake rate. Contrary...
متن کاملUse of passive sampling devices for monitoring and compliance checking of POP concentrations in water.
BACKGROUND The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent organic pollutants (POPs) targeted by the Stockholm Convention are nonpolar or weakly ...
متن کاملValidation and application of an analytical method for determination of Persistent Organic Pollutants in Rainbow trout (Onchorhynchus mykiss) collected from Tehran retail markets
Persistent organic pollutants are a wide group of toxic and dangerous compounds. These organic compounds are chemically and physically stable even beams. In this study an analysis method for simultaneous determination of 18 persistent organic pollutants including eleven Organochlorine pesticides (OCPs): HCB, Dieldrin, Methoxychlor, α-, ϒ-Chlordane, α-, β-Endosulfan and o,p’-DDE, p,p’-DDE, o,p’-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Environmental pollution
دوره 164 شماره
صفحات -
تاریخ انتشار 2012