Contact lens-related adverse events and the silicone hydrogel lenses and daily wear care system used.
نویسندگان
چکیده
OBJECTIVE To investigate the incidence of adverse events related to the use of varying silicone hydrogel contact lens and lens solution combinations. METHODS Individuals with myopia (N = 558) participated in 1 or more of approximately 40-participant trials in a matrix of 20 silicone hydrogel contact lens and lens-solution combinations. Visits were at baseline, 2 weeks, 1 month, and 3 months. The mean study completion rate was 90% of the expected participant-months (final data set: 840 lens-solution combinations and 2271 participant-months). Adverse events were reported as the first occurrence of each type per 100 participant-months for each lens-solution combination. RESULTS The rate of all corneal infiltrative events (CIEs) was 3.1 per 100 participant-months (range, 0-10.5), and the rate of symptomatic CIEs was 1.7 per 100 participant-months (range, 0-10.5), including 1 case of microbial keratitis (0.04 per 100 participant-months). Rates for CIEs differed substantially among solution groups, with hydrogen peroxide having the lowest rate (0.6 per 100 participant-months; range, 0-0.9). The rate was 0.8 per 100 participant-months (range, 0-8.0) for superior epithelial arcuate lesions, which varied by lens type, 0.04 per 100 participant-months (1 case only) for corneal erosion, and 0.4 per 100 participant-months (range, 0-2.0) for contact lens papillary conjunctivitis, which was modified by type of solution. The rate of solution-induced corneal staining for all lens-solution combinations was 4.7 per 100 participant-months (range, 0-23) and varied significantly based on lens-solution combination (P < .001). CONCLUSIONS The frequency of adverse events varied with silicone hydrogel contact lens and lens solution combinations, with hydrogen peroxide having the lowest incidence of CIEs and solution-induced corneal staining, indicating that lens material and design, type of solution, and solution-lens interactions are likely contributing factors in this mode of lens wear.
منابع مشابه
Adhesion of Pseudomonas aeruginosa and Staphylococcus epidermidis to silicone-hydrogel contact lenses.
PURPOSE The purpose of this study is to compare the adhesion capabilities of the most important etiologic agents of microbial ocular infection to the recently available silicone-hydrogel lenses with those to a conventional hydrogel lens. METHODS In vitro static adhesion assays of Pseudomonas aeruginosa 10,145, Staphylococcus epidermidis 9142 (biofilm-positive), and 12,228 (biofilm-negative) t...
متن کاملIncidence of keratitis of varying severity among contact lens wearers.
AIM To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. METHODS A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate be...
متن کاملEffects of daily irrigation on corneal epithelial permeability and adverse events with silicone hydrogel contact lens continuous wear.
PURPOSE To determine whether daily irrigation with sterile saline solution during silicone hydrogel (SiH) contact lens continuous wear (CW) can mitigate increases in corneal epithelial permeability (Pdc) and reduce the risk of adverse events. METHODS In this study, 161 non-contact lens wearers were fit with SiH contact lenses and randomized to either a treatment (n = 81) or control (n = 80) g...
متن کاملAntimicrobial Efficacy of Contact Lens Care Solutions Against Neutrophil-Enhanced Bacterial Biofilms
PURPOSE Neutrophil-derived extracellular debris has been shown to accelerate bacterial biofilm formation on hydrogel and silicone hydrogel contact lens surfaces compared to lenses inoculated with bacteria alone. The purpose of this study was to evaluate the disinfection efficacy of four standard commercial contact lens cleaning regimens against neutrophil-enhanced bacterial biofilms formed on s...
متن کاملThe future of silicone hydrogels.
Significant advances during the past decade in silicone hydrogel lenses have made them the primary mode for new contact lens wear. Their dominance in the market place is driven largely by the elimination of structural and physiological changes induced by contact lens-induced hypoxia, as exemplified especially by the reduction in limbal redness. However, end-of-day dryness and discomfort still d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 127 12 شماره
صفحات -
تاریخ انتشار 2009