Quantitative determination of aortic regurgitant volumes in dogs by ultrafast computed tomography.
نویسندگان
چکیده
Current imaging modalities can provide only a qualitative or semiquantitative measure of the severity of aortic regurgitation. Ultrafast computed tomography (CT) has the capability of rapid imaging (17 frames/sec) coupled with high spatial resolution (1.5 mm2). Eight millimeter thick images can be acquired to interrogate simultaneously the right and left ventricles. End-diastolic and end-systolic tomograms can be reconstructed serially from apex to base by Simpson's rule to provide end-diastolic and end-systolic volumes from which the right and left ventricular stroke volumes can be derived. To determine whether the difference between left and right ventricular stroke volume measured with ultrafast CT could be used to estimate the volume of experimentally induced aortic regurgitation, we studied six dogs in which proximal aortic electromagnetic flow probes had been implanted. Varying degrees of aortic regurgitation were induced by manipulation of a basket catheter through the aortic valve. During suspended respiration in the control state in the absence of aortic regurgitation, right and left ventricular stroke volumes measured with ultrafast CT were nearly identical (mean difference 1.0 +/- 1.2 ml [mean +/- SE]). In the presence of varying degrees of aortic regurgitation, regurgitant volume derived by ultrafast CT as the difference between right and left ventricular stroke volumes correlated closely to the regurgitant volume measured by the electromagnetic flow probe (r = .99, slope = .92, y intercept = 0.98 ml, SEE = 1.02 ml, n = 16). Regurgitant fraction also correlated closely to the regurgitant fraction measured by the electromagnetic flow probe (r = .94, slope = .98, y intercept = 0.66%, SEE = 4.73%, n = 16).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Morphological and Functional Evaluation of Quadricuspid Aortic Valves Using Cardiac Computed Tomography
OBJECTIVE The aim of this study was to identify the morphological and functional characteristics of quadricuspid aortic valves (QAV) on cardiac computed tomography (CCT). MATERIALS AND METHODS We retrospectively enrolled 11 patients with QAV. All patients underwent CCT and transthoracic echocardiography (TTE), and 7 patients underwent cardiovascular magnetic resonance (CMR). The presence and ...
متن کاملQuantitative Doppler assessment of valvular regurgitation.
BACKGROUND Quantitation of valvular regurgitation remains a challenge. The accuracy of quantitative Doppler is controversial, and its ability to measure regurgitant volume is unknown; therefore, it is not widely used. METHODS AND RESULTS In 120 patients (20 without regurgitation, 19 with aortic regurgitation, and 81 with mitral regurgitation), the stroke volume through the mitral annulus and ...
متن کاملQuantification of aortic valvular regurgitation in dogs by nuclear imaging.
Radionuclide gated cardiac blood pool (GBP) imaging was used to quantitatively assess the severity of acute aortic valvular regurgitation produced experimentally in 10 anesthetized dogs. Right ventricular (RV) and left ventricular (LV) stroke counts (end-diastolic minus end-systolic counts in RV and LV regions of interest) were used as indices of the stroke volumes of the two ventricles. Regurg...
متن کاملQuantitative Doppler-Echocardiographic Determination of Regurgitant Volume in Patients with Aortic Insufficiency
BACKGROUND The severity of aortic regurgitation (AR) can be determined by invasive or echocardiographic methods. We systematically compared quantitative invasive and echocardiographic data with semiquantitative invasive grades in a prospective series of patients. METHODS Using Doppler-echocardiography we determined the cardiac output over the aortic, pulmonary and mitral valve in 27 patients ...
متن کاملAnalysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI
PURPOSE The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. METHODS left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-qua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 76 3 شماره
صفحات -
تاریخ انتشار 1987