The Use of Polarization Filters to Detect the Edge of the Descemet’s Stripping Automated Endothelial Keratoplasty(DSAEK) Graft
نویسندگان
چکیده
PURPOSE To report the technique of combining the two different polarization filters to detect the flap edge of the corneoscleral tissue before trephining the Descemet's stripping automated endothelial keratoplasty (DSAEK) tissue. METHODS A human DSAEK donor tissue was prepared with mechanical microkeratome and the tissue on the cutting block was brought under the microscope. The liner, circular, or the combination of these two polarization filters was placed between the tissue and the microscope. The tissue images were taken with digital camera under either of 3 settings. RESULTS The combination of circular and linear polarization filters enabled us to recognize the edge of the flap more easily than others. CONCLUSION This simple system with polarization filters was effective in clear visualization of the flap edge during DSAEK tissue preparation. These features may significantly enhance safety of various surgical procedures, in addition to DSAEK tissue preparation.
منابع مشابه
Descemet’s Stripping Automated Endothelial Keratoplasty – A Review
Descemet’s stripping automated endothelial keratoplasty (DSAEK) has become the procedure of choice to treat corneal endothelial dysfunction. The technique involves replacing the diseased host endothelium with a graft consisting of a thin layer of posterior stroma, Descemet’s membrane and endothelium. In comparison with penetrating keratoplasty (PK), DSAEK confers quicker visual and structural r...
متن کاملDonor and surgical risk factors for primary graft failure following Descemet’s stripping automated endothelial keratoplasty in Asian eyes
BACKGROUND Descemet's stripping automated endothelial keratoplasty (DSAEK) has been shown to have superior refractive and visual results compared with penetrating keratoplasty, but higher rates of primary graft failure (PGF). This paper presents donor and surgical risk factors for PGF in DSAEK cases in Asian eyes. DESIGN Retrospective case-control study. PARTICIPANTS All consecutive patient...
متن کاملFactors associated with graft survival and endothelial cell density after Descemet’s stripping automated endothelial keratoplasty
Postoperative endothelial cell loss leads to graft failure after corneal transplantation, and is one of the important issues for long-term prognosis. The objective of this study was to identify clinical factors affecting graft survival and postoperative endothelial cell density (ECD) after Descemet's stripping automated endothelial keratoplasty (DSAEK). A total of 198 consecutive Japanese patie...
متن کاملEndothelial cell counts after Descemet’s stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes
BACKGROUND The purpose of this study was to compare endothelial cell counts after Descemet's stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty in Asian eyes. METHODS This was a retrospective study of patients from our prospective Singapore Corneal Transplant Study cohort who received corneal transplantation in 2006-2008. We compared eyes that underwent DSAEK or...
متن کاملDescemet’s stripping automated endothelial keratoplasty for congenital hereditary endothelial dystrophy
Congenital hereditary endothelial dystrophy (CHED), presents in infancy or early childhood with bilateral clouding of corneas. This condition has previously been managed surgically with penetrating keratoplasty (PKP). Performing PKP in pediatric patients has its own set of difficulties. More recently, there has been growing interest in treating this condition with Descemet's stripping automated...
متن کامل