Delayed treatment of traumatic rupture of the thoracic aorta with endoluminal covered stent.
نویسندگان
چکیده
BACKGROUND Stent grafting is emerging as a new treatment for several pathological conditions involving the thoracic aorta. We studied the feasibility and safety of this technique for delayed treatment of ruptures of the aortic isthmus. METHODS AND RESULTS Nine patients (14 to 76 years old; mean, 37 years; male/female ratio, 8/1) underwent stent grafting of the aortic isthmus in subacute (n=5) or chronic (n=4) aortic traumatic rupture after a motor accident. In subacute ruptures, this treatment was delayed (1 to 8 months; mean, 5.4 months) because of the severity of other associated injuries. Stent grafting was technically successful (defined as complete exclusion of the pseudoaneurysmal sac) in all patients. Short-term fever and biological inflammatory syndrome occurred in 3 patients. Two major complications occurred: in 1 patient, an early occlusion of the left subclavian artery was treated by placement of 2 Palmaz stents. In another patient, an atelectasis related to an increase of preexisting compression of the left main bronchus by the pseudoaneurysmal sac was successfully treated by temporary placement of an endobronchial silicone stent. Mean follow-up was 11.6 months (range, 3 to 21 months). Thrombosis of the pseudoaneurysmal sac was found in all patients. CONCLUSIONS In the absence of available extended follow-up about the safety and effectiveness of endovascular grafting, this approach seems to be a viable therapeutic option for traumatic rupture of the aortic isthmus, but appropriately controlled prospective studies are needed before we can recommend its widespread use.
منابع مشابه
[Traumatic aortic injuries in severely injured patients].
Herein we report our results of treatment of traumatic aortic ruptures in severely injured patients with either open surgery or endovascular stent graft repair. Data were analyzed retrospectively from the trauma registry of the DGU (Deutsche Gesellschaft fur Unfallchirurgie) over a time period from 1993 through 2002. All patients with traumatic rupture of the aorta were included and analyzed fo...
متن کاملConventional surgical repair and endovascular treatment of acute traumatic aortic rupture.
OBJECTIVE Endoluminal aortic stent grafting offers a potentially less invasive alternative to open chest surgery, especially in patients with polytrauma. We compare the results of conventional surgical repair and endovascular treatment of traumatic aortic rupture. METHODS Retrospectively, 74 patients with acute traumatic aortic rupture were analyzed. Most of the patients had a rupture limited...
متن کاملEndovascular stent-grafting for diseases of the descending thoracic aorta.
PRINCIPLES Endoluminal stent-grafts are emerging as a less invasive alternative to conventional open surgery in the management of descending thoracic aortic dissections and aneurysms. We describe our experience with endovascular stent-grafting in the treatment of thoracic aorta pathology. METHODS 17 Patients were treated with 23 endovascular stents. The underlying pathology was an atheroscler...
متن کاملAcute Traumatic Thoracic Aortic Injury: Considerations and Reflections on the Endovascular Aneurysm Repair.
Traumatic rupture of the thoracic aorta is a life-threatening lesion and it occurs in 10 to 30% of fatalities from blunt thoracic trauma and is the second most common cause of death after head injury. Immediate surgery is often characterized by a high mortality and morbidity rate. Delayed repair of traumatic aortic injuries has significant survival benefits and a much lower mortality rate compa...
متن کاملDelayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report
BACKGROUND We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture. CASE PRESENTATION In 7th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG® 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no sig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 99 4 شماره
صفحات -
تاریخ انتشار 1999