The applications of a commercial gas/liquid separator coupled with an inductively coupled plasma mass spectrometer

نویسندگان

  • Peter Hitchen
  • Robert Hutton
  • Christopher Tye
چکیده

A commercially available hydride generator, with a novel membrane gas-liquid separator, has been coupled to a new ICPMS instrument which itself features many unique design considerations. Little or no optimization of the mass spectrometer or ionization source was required to obtain excellent analytical data; and a variety of matrices have been analysed.The elements As and Se are usually used to demonstrate the effectiveness of a hydride generation system, and these are of particular importance, bearing in mind potential Ar molecular overlaps with isotopes of interest. The flexibility of the hydride generation ICP-MS system is highlighted, with the inclusion of analytical figures of merit for the elements Sn, Sb, Ge and Hg, as well as As and Se. Data obtained by 'standard' pneumatic nebulization on the ICP-MS is compared with that obtained with the hydride generator for all of the elements.Improvements of between 50 and 100 times were gained in measurements of three sigma detection limits for all elements in the determinations, including Hg. Measurements were made on several isotopes for particular elements, and the data is included for the purposes of comparison. Stabilities of between 1 and 2.5% were obtained for 0.5 ppb solutions over 10 min measurement periods, all data is presented without using an internal standard.Finally, analytical data from seawater standards, spiked with low levels of As and Se and calibrated against aqueous standards, demonstrate excellent recoveries. This is of particular interest bearing in mind the well-documented molecular interferences from high chloride matrices on As and Se analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trace analyses of arsenic in drinking water by inductively coupled plasma mass spectrometry: high resolution versus hydride generation.

A magnetic sector inductively coupled plasma mass spectrometer (ICPMS) was applied to the determination of arsenic in drinking water samples using standard liquid sample introduction in the high-resolution mode (M/delta M = 7800) and hydride generation in the low-resolution mode (M/delta M = 300). Although high mass resolution ICPMS allowed the spectral separation of the argon chloride interfer...

متن کامل

Investigation of Slug Suppression System in Deepwater Scenario

In pipeline-riser systems, pressure fluctuations which result from the formation of large liquid slugs and gas surges due to operational changes or low mass flow rate from production wells and the profile of pipeline-riser systems often lead to trips at the inlet of the separator; and thereby, the problem causes a a loss of the production.In this study, on a sample deep-water oil field off the ...

متن کامل

A Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application

An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...

متن کامل

Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis.

Inductively coupled plasma mass spectrometry (ICP-MS) is now a well established detection technique for liquid chromatography, gas chromatography, supercritical fluid chromatography and capillary electrophoresis. A review of the literature with particular regard to ICP-MS as a chromatographic and capillary electrophoretic detector is presented. The various modes of chromatography and capillary ...

متن کامل

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 14  شماره 

صفحات  -

تاریخ انتشار 1992