Evaluation of HE4, CA-125, Risk of Ovarian Malignancy Algorithm (ROMA) and Risk of Malignancy Index (RMI) in the Preoperative Assessment of Patients with Adnexal Mass.
نویسندگان
چکیده
OBJECTIVES To evaluate the validity and compare the performance of cancer antigen-125 (CA-125), human epididymis protein 4 (HE4), the risk of malignancy index (RMI), and the risk of ovarian malignancy algorithm (ROMA) in the diagnosis of ovarian cancer in patients with ovarian lesions discovered during their preoperative work-up investigations. METHODS This prospective, cross-sectional study looked at patients who attended the gynecology department at the Royal Hospital, Muscat, from 1 March 2014 to 30 April 2015, for the evaluation of an ovarian lesion. The inclusion criteria included women who underwent surgical intervention and who had a preoperative pelvic ultrasound with laboratory investigation for CA-125 and HE4. The study validated the diagnostic performance of CA-125, RMI, HE4, and ROMA using histopathological diagnosis as the gold standard. RESULTS The study population had a total of 213 cases of various types of benign (77%) and malignant (23%) ovarian tumors. CA-125 showed the highest sensitivity (79%) when looking at the total patient population. When divided by age, the sensitivity was 67% in premenopausal women. In postmenopausal women, CA-125 had lower sensitivity (89%) compared to RMI, HE4, and ROMA (93% each). A high specificity of 90% was found for HE4 in the total patient population, 93% in premenopausal women and 75% in postmenopausal women. CA-125 had the highest specificity (79%) in postmenopausal women. Both CA-125 and RMI were frequently elevated in benign gynecological conditions particularly in endometriosis when compared to HE4 and ROMA. We also studied modifications of the optimal cut-offs for the four parameters. Both CA-125 and RMI showed a significant increase in their specificity if the cut-off was increased to ≥ 60 U/mL for CA-125 and to ≥ 250 for RMI. For HE4, we noted an improvement in its specificity in postmenopausal women when its cut-off was increased to140 pmol/L. CONCLUSIONS HE4 and ROMA showed a very high specificity, but were less sensitive than CA-125 and RMI in premenopausal women. However, they were of comparable sensitivity in postmenopausal women and were valuable in distinguishing benign ovarian tumors or endometriosis from ovarian cancer. Modifying the cut-off values of the different markers resulted in a higher accuracy compared to the standard cut-offs, but at the expense of reduced sensitivity.
منابع مشابه
Evaluation of diagnostic accuracy of RMI and ROMA indices in comparison to HE4 and CA125 parameters for estimating the risk of malignancy of adnexal masses.
Background: Ovarian cancer is the fifth leading cancer-related cause of death in women worldwide and is often diagnosed at advanced stages. Regarding the low sensitivity and specificity of the currently available diagnostic techniques, in the present study, we aimed to evaluate the accuracy of RMI and ROMA indexes and comparing these two indexes with CA-125 and HE4 parameters for the diagnosis ...
متن کاملRisk of malignancy index as an evaluation of preoperative pelvic mass
Background: Risk of malignancy index (RMI) is the best method for discriminating benign and malignant pelvic masses. The aim of this study was to determine the RMI for preoperative evaluation of pelvic mass. Methods: This study was performed on 182 women with adenexal mass referred to Yahyahnejiad Hospital of Babol University of Medical Sciences in Iran from 2007 to 2009.The sensitivity, specif...
متن کاملComparing the Diagnostic Value of the Risk of Ovarian Malignancy Algorithm and CA125 in Patients with Ovarian Mass
Background and purpose: Ovarian cancer is the fourth leading cause of death from gynecological cancers in women. Using specific tumor markers that help in making diagnosis at early stages improve therapeutic outcomes. The purpose of this study was to evaluate the diagnostic value of the Risk of Ovarian Malignancy Algorithm (ROMA) index in patients with ovarian mass. Materials and methods: A cr...
متن کاملA comparison of CA125, HE4, risk ovarian malignancy algorithm (ROMA), and risk malignancy index (RMI) for the classification of ovarian masses
OBJECTIVE Differentiation between benign and malignant ovarian neoplasms is essential for creating a system for patient referrals. Therefore, the contributions of the tumor markers CA125 and human epididymis protein 4 (HE4) as well as the risk ovarian malignancy algorithm (ROMA) and risk malignancy index (RMI) values were considered individually and in combination to evaluate their utility for ...
متن کاملModification of cutoff values for HE4, CA125, the Risk of Malignancy Index, and the Risk of Malignancy Algorithm for ovarian cancer detection in Jakarta, Indonesia.
BACKGROUND CA125 and HE4 are used in calculating Risk of Malignancy Algorithm (ROMA); and Risk of Malignancy Index (RMI). However, studies showed that normal levels of CA125, and HE4 differ among ethnicities such as between Asians and Caucasians, thus affecting the accuracy of the RMI score and ROMA in predicting ovarian malignancy. This study aimed to determine whether new or modified cutoff v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Oman medical journal
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2016