Tygon" Roller Pump Tubing

نویسندگان

  • Edward J. Snyder
  • James A. Cullen
چکیده

A failure analysis was performed on Norton S-65-HL Tygon® tubing. Fatigue testing was performed on four sizes of this tubing, and essentially showed how the tubing wears out. A dynamic "life hours to failure" test, which was performed on the 3/8" internal diameter (ID) size, quantified when the tubing ruptured. Based on results of laboratory testing and the institution's clinical extracorporeal membrane oxygenation (ECMO) experience, a reasonable life expectancy for the 3/8" S-65-HL Tygon® size was determined for use in this institution's neonatal ECMO system. An understanding of the expected performance of roller pump tubing an integral component of the ECMO system is imperative to providing safe, effective extracorporeallife support. Volume 28, Number 2, June 1996 Address correspondence to: Edward J. Snyder, CBET, Supervisor Department of Biomedical Instrumentation 520 Main Building Thomas Jefferson University Hospital 1 020 Sanson Street Philadelphia, PA 19107

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tubing failure during prolonged roller pump use: a laboratory study.

Little is known about the mechanical forces acting on extracorporeal circuit tubing with prolonged roller pump use during extracorporeal membrane oxygenation (ECMO). We examined the time to tubing rupture of three different materials during actual roller pump use, mean and standard deviation (SD) (SD shown in parentheses): Tygon (control) 243.7 h (175.4); LVA 121 h (14.3); and SRT 6.6 h (2.1). ...

متن کامل

A Comparison of Static Occlusion Setting Methods : Fluid Drop Rate and Pressure Drop

Tubing circuits primed with water were constructed on two roller pumps to characterize and compare two static methods of setting the occlusion on roller pumps (fluid drop rate and pressure drop rate). Twelve separate experiments were performed in which PVC boot tubing diameters (1/2 in, 3/8 in and 1/4 in), roller position (each roller alone on a two roller pump) and roller occlusion (total occl...

متن کامل

Roller Pump Induced Tubing Wear: Another Argument in Favor of Arterial Line Filtration

____________ _ Pump head tubing was studied to determine if internal wear occurred during routine cardiopulmonary bypass. Several segments of silicone rubber tubing were examined in a scanning electron microscope following clinical perfusion. In each case, the proper degree of occlusion had been set just prior to beginning bypass. The roller pump was a six-inch dual roller type, and the tubing ...

متن کامل

The use of plastic tubing in roller pumps.

If plastic tubing is to be used in roller pumps for propelling blood in extracorporeal circulations under occlusive conditions spring loading the rollers and accurately setting the spring force is essential. Various types and sizes of plastic tubing are compared and their performance estimated; rubber tubing used for the same purpose has been tested. The optimum spring force has been determined...

متن کامل

Toxic effects of latex and Tygon tubing on marine phytoplankton, zooplankton and bacteria

Natural plankton assemblages were incubated with a small piece of silicone. Tygon or latex rubber tubing in 200 m1 of culture to determine potential long-term toxic effects of the tubing. Drastic decreases in cell numbers and chlorophyll fluorescence indicated that over 95 "h of the phytoplankton were killed by the latex rubber tubing in 4 d. Even a 1 mm piece of latex tubing lulled -90 % of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997