Effect of Coil Geometry on Frost-Free Finned-Tube Evaporator Performance

نویسندگان

  • Christian J. L. Hermes
  • Marco E. Marques
  • Claudio Melo
  • Joaquim M. Goncalves
  • C. J. L. HERMES
  • M. E. MARQUES
  • C. MELO
  • J. M. GONÇALVES
چکیده

This paper outlines a mathematical modelling approach to predict the steady-state behaviour of finned-coil evaporators. The model was built taking three domains into account: (i) refrigerant flow inside the coil; (ii) heat transfer through the walls; and (iii) air flow through the finned-coil array. The equations were obtained from the mass, momentum and energy conservation principles, mathematically written according to their one-dimensional differential formulation. Comparisons with experimental data were carried out and it was found that the model predictions, in terms of cooling capacity, refrigerant superheating, and outlet air temperature, were within an acceptable error band. The main contribution of this work is the thermal performance evaluation of two different evaporator designs under various operating conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat and Mass Transfer Coefficients Under Frost Conditions In A Finned-Tube Evaporator

The objectives of this study are to provide experimental data and a correlation that can be used in the optimal design of an evaporator under frost conditions. In the present study, we tested both a single stage and a two-stage evaporator with a variation of operating parameters and fin geometry under frost conditions. The effects of tube space and fin alignment on the heat transfer performance...

متن کامل

Performance Evaluation Of Peripheral-Finned Tube Evaporators Under Frosting Conditions

The peripheral finned-tube (PFT) is a novel air-side geometry for compact heat exchangers. Previous studies (Pussoli et al., 2012) evaluated the thermal-hydraulic performance of the PFT geometry under dry conditions (i.e., no frost or condensate formation on the air side). The present study focuses on quantifying the thermal-hydraulic performance of the PFT geometry under frosting conditions. A...

متن کامل

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

An experimental investigation was implemented to determine the capacity degradation due to non-uniform refrigerant and air flow distributions, and to assess the potential to recover the lost capacity via controlling refrigerant distribution between individual refrigerant circuits. The tests were performed on a three-circuit, threedepth-row, finned-tube evaporator. Refrigerant inlet quality, exi...

متن کامل

Effects of Condensate and Initial Formation of Thin Frost Layer on Evaporator Coil Performance of Room Air-Conditioners

This study investigated experimentally and theoretically, how condensate and initial formation of a thin frost layer on the surface of the evaporator affects the evaporator performance of room air-conditioners compared to dry coil conditions. The theoretically obtained results were validated with the measured values in both wet and initial frost formation conditions and a good correlation was f...

متن کامل

Selection of Capillary Tube for Refrigeration System

Proper selection of capillary tube it is essential to study the effect of capillary tube geometry on the performance of refrigeration systems. The literature review is focused on the influence of geometrical parameters like tube length, diameter, coil pitch, number of twist and twisted angle on pressure drop and coefficient of performance (COP) of the system. These parameters can be optimized u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014