Higher-energy collision-activated dissociation without a dedicated collision cell.
نویسندگان
چکیده
Beam-type collisional activation dissociation (HCD) offers many advantages over resonant excitation collision-activated dissociation, including improved identification of phosphorylated peptides and compatibility with isobaric tag-based quantitation (e.g. tandem mass tag (TMT) and iTRAQ). However, HCD typically requires specially designed and dedicated collision cells. Here we demonstrate that HCD can be performed in the ion injection pathway of a mass spectrometer with a standard atmospheric inlet (iHCD). Testing this method on complex peptide mixtures revealed similar identification rates to collision-activated dissociation (2883 versus 2730 IDs for iHCD/CAD, respectively) and precursor-product-conversion efficiency comparable to that achieved within a dedicated collision cell. Compared with pulsed-q dissociation, a quadrupole ion trap-based method that retains low-mass isobaric tag reporter ions, iHCD yielded isobaric tag for relative and absolute quantification reporter ions 10-fold more intense. This method involves no additional hardware and can theoretically be implemented on any mass spectrometer with an atmospheric inlet.
منابع مشابه
Kinetics of Surface-Induced Dissociation of N(CH <Subscript>3 </Subscript>) <Stack> <Subscript>4 </Subscript> <Superscript>+ </Superscript> </Stack> and N(CD <Subscript>3 </Subscript>) <Stack> <Subscript>4 </Subscript> <Superscript>+ </Superscript> </Stack> Using Silicon Nanoparticle Assisted Laser Desorption/Ionization and Laser Desorption/Ionization
The implementation of surface-induced dissociation (SID) to study the fast dissociation kinetics (sub-microsecond dissociation) of peptides in a MALDI TOF instrument has been reported previously. Silicon nanoparticle assisted laser desorption/ionization (SPALDI) now allows the study of small molecule dissociation kinetics for ions formed with low initial source internal energy and without MALDI...
متن کاملTandem fourier transform mass spectrometry studies of surface-induced dissociation of benzene monomer and dimer ions on a self-assembled fluorinated alkanethiolate monolayer surface.
A new instrument configuration based on a Finnigan FTMS-2000 platform has been applied to the study of surface-induced dissociation (SID) in this research. Benzene monomer ions C(6)H(6)(+) and dimer ions (C(6)H(6))(2)(+) were impacted on a fluorinated self-assembled monolayer surface at collision energies ranging from 1 to 70 eV. Benzene cations were chosen for this study because the fragmentat...
متن کاملSurface-Induced Dissociation Mass Spectra as a Tool for Distinguishing Different Structural Forms of Gas-Phase Multimeric Protein Complexes.
One attractive feature of ion mobility mass spectrometry (IM-MS) lies in its ability to provide experimental collision cross section (CCS) measurements, which can be used to distinguish different conformations that a protein complex may adopt during its gas-phase unfolding. However, CCS values alone give no detailed information on subunit structure within the complex. Consequently, structural c...
متن کاملEffect of Induced Dipole-Induced Dipole Potential and the Size of Colliding Particles on Ion-Quadrupolar Molecule Collision Rate Constants
Classical trajectory (Monte Carlo) calculation is used to calculate collision rate constants of ion-quadrupolar molecule interactions for the H¯+C2H2 system. The method presented here takes into account the effect of the induced dipole-induced dipole potential on ion-quadrupolar molecule collision rate constants. It is also assumed that the colliding particles have a d...
متن کاملAnalysis of Isotopic Labeling in Peptide Fragments by Tandem Mass Spectrometry
Phenotype in multicellular organisms is the consequence of dynamic metabolic events that occur in a spatially dependent fashion. This spatial and temporal complexity presents challenges for investigating metabolism; creating a need for improved methods that effectively probe biochemical events such as amino acid biosynthesis. Isotopic labeling can provide a temporal-spatial recording of metabol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Molecular & cellular proteomics : MCP
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2011