Retinal nerve fibre layer polarimetry: histological and clinical comparison.

نویسندگان

  • J E Morgan
  • A Waldock
  • G Jeffery
  • A Cowey
چکیده

AIMS To compare histological thickness of the retinal nerve fibre layer in the primate with retardation measurements obtained in vivo using the Mark II Nerve Fiber Analyzer (NFA, Laser Diagnostic Technologies, San Diego, USA). METHODS Scanning laser polarimetry was performed on both eyes of a healthy anaesthetised adult primate (Macaca mulatta). The retinal nerve fibre layer thickness was measured in the eye with the best polarimetry image. A nerve fibre layer thickness map was scaled and aligned to a retardation map to permit correlation of retardation and thickness measurements. RESULTS Retinal nerve fibre layer thickness measurements could be satisfactorily aligned with corresponding retardation values at 216 locations. The overall correlation coefficient for nerve fibre layer thickness and retardation was r = 0.70 (n = 216, p < 0.001). Regional comparison showed the best correlation (r = 0.76, n = 45, p < 0.001) occurred inferior to the optic disc. Less positive but still highly significant correlations were seen superiorly and temporally (r = 0.52, n = 26, p = 0.007 and r = 0.49, n = 86, p = < 0.001 respectively), with the lowest correlation occurring at the nasal aspect of the disc (r = 0.06, n = 67, p = 0.64). CONCLUSIONS In the primate eye, retinal nerve fibre layer thickness shows a positive correlation with retardation measurements obtained with the nerve fibre analyser. However, since the correlation coefficient varied around the optic disc, further evaluation of the device is advised before its routine clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma

BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...

متن کامل

Axonal loss from acute optic neuropathy documented by scanning laser polarimetry.

BACKGROUND/AIMS Retinal nerve fibre layer analysis by scanning laser polarimetry has been shown to facilitate diagnosis of glaucoma while its role in glaucoma follow up is still unclear. A major difficulty is the slow reduction of retinal nerve fibre layer thickness in glaucomatous optic neuropathy. Eyes of patients were studied after acute retrobulbar optic nerve lesion in order to evaluate th...

متن کامل

Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry.

AIMS Scanning laser polarimetry is a new technique allowing quantitative analysis of the retinal nerve fibre layer in vivo. This technique was employed to investigate the variation of the retinal nerve fibre layer thickness in a group of normal subjects of different ages and ethnic groups. METHODS 150 normal volunteers of different ages and ethnic groups were recruited for this study. Three c...

متن کامل

Scanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucoma.

AIMS To evaluate the clinical value of scanning laser polarimetry with the nerve fibre analyser type II in primary open angle glaucoma (POAG) and capsular glaucoma. METHODS Scanning laser polarimetry was performed on one eye of 30 patients suffering from POAG, 25 patients suffering from capsular glaucoma, and on 35 healthy control subjects. The retinal nerve fibre layer (RNFL) thickness value...

متن کامل

Evaluating the optic nerve and retinal nerve fibre layer: the roles of Heidelberg retina tomography, scanning laser polarimetry and optical coherence tomography.

INTRODUCTION For many years, ophthalmologists have looked at the optic nerve head to evaluate the status of glaucoma. Clinical examination of the optic nerve head and retinal nerve fibre layer (RNFL) is however, subjective and sometimes variable. Recent developments in computer-based imaging technologies have provided a means of obtaining quantitative measurements of the optic nerve head topogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 6  شماره 

صفحات  -

تاریخ انتشار 1998