Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded)
نویسندگان
چکیده
Objective. To share our experience of cerebrospinal fluid gusher in cochlear implantation in patients with enlarged cochlear or vestibular aqueduct. Study Design. Case series with comparison and a review of the literature. Methods. A retrospective study was performed. Demographic and radiological results of patients with enlarged cochlear aqueduct or enlarged vestibular aqueduct in 278 consecutive cochlear implant recipients, including children and adults, were evaluated between January 2000 and December 2015. Results. Six patients with enlarged cochlear aqueduct and eight patients with enlarged vestibular aqueduct were identified. Cerebrospinal fluid gusher occurs in five subjects with enlarged cochlear aqueduct and in only one case of enlarged vestibular aqueduct. Conclusion. Based on these findings, enlarged cochlear aqueduct may be the best risk predictor of cerebrospinal fluid gusher at cochleostomy during cochlear implant surgery despite enlarged vestibular aqueduct.
منابع مشابه
Cochlear Implantation in Isolated Large Vestibular Aqueduct Syndrome: Report of Three Cases and Literature Review
Introduction Large vestibular aqueduct syndrome (LVAS) is characterized by the enlargement of the vestibular aqueduct associated with sensorineural hearing loss. It is the most common radiographically detectable inner ear anomaly in congenital hearing loss. LVAS may occur as an isolated anomaly or in association with other inner ear malformations. Objective To report three cases of isolated LVA...
متن کاملInfluence of an intraoperative perilymph gusher on cochlear implant performance in children with labyrinthine malformations.
OBJECTIVES To assess the effect of an intraoperative perilymph fluid gusher during cochlear implantation on speech perception abilities in pediatric patients with labyrinthine anomalies. SETTING Tertiary care academic referral center. METHODS Seventy subjects with labyrinthine malformations who received a cochlear implant were identified in our pediatric cochlear implant database. In 30 cas...
متن کاملMisdiagnosis of otosclerosis in a patient with enlarged vestibular aqueduct syndrome: a case report
INTRODUCTION In the present case we report on the mismanagement of a patient misdiagnosed with otosclerosis, who was subsequently found to have enlarged vestibular aqueduct syndrome bilaterally. This highlights the need to not only be vigilant in pre-operative assessment of otosclerosis but also in post-operative investigations of stapedectomy failures. CASE PRESENTATION Our patient, a 56-yea...
متن کاملVariations in the cochlear implant experience in children with enlarged vestibular aqueduct.
OBJECTIVES/HYPOTHESIS To describe the clinical experience and characterize the outcomes of cochlear implantation (CI) in children with isolated enlarged vestibular aqueduct (IEVA) as compared to children with enlarged vestibular aqueduct (EVA) associated with other bony labyrinth abnormalities. STUDY DESIGN Single, tertiary care, institutional retrospective review over 2 decades. METHODS Th...
متن کاملUse of Intrathecal Fluorescein in Recurrent Meningitis after Cochlear Implantation-A Case Report
Introduction: Congenital anomalies of the cochlea and labyrinth can be associated with meningitis and varying degrees of hearing loss or deafness. Despite antibiotics, meningitis remains a life threatening complication. Case Report: We report a case of recurrent meningitis following episodes of otitis media in a cochlear implantee child with bilateral vestibulocochlear malformation, due to f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016