BACKGROUND AND OBJECTIVES A free-beam-type CO2 laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO2 laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. SUBJECTS AND METHODS The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO2 lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. RESULTS The mean operating time was significantly (p=0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly (p=0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly (p=0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. CONCLUSIONS Operating times were significantly shorter using the fiber-type CO2 laser, while hearing outcomes did not differ significantly between the two groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using of Broadened Asymmetric Waveguide Structure for 980nm Diode Laser

Laser diode beam divergence is the main parameter for beam shaping and fiber optic coupling. Increasing the waveguide layer thickness is the conventional method to decrease the beam divergence. In this paper, the broadened asymmetric waveguide is introduced to decrease the divergence without increasing the optical power. The asymmetric waveguide was used to shift the vertical optical field to n...

متن کامل

Free Vibrations of Continuous Grading Fiber Orientation Beams on Variable Elastic Foundations

Free vibration characteristics of continuous grading fiber orientation (CGFO) beams resting on variable Winkler and two-parameter elastic foundations have been studied. The beam is under different boundary conditions and assumed to have arbitrary variations of fiber orientation in the thickness direction. The governing differential equations for beam vibration are being solved using Generalized...

متن کامل

Usages of Laser (Co2 -Type) in Neurological Surgery

SUMMARY We have discussed in this article, about usages of Laser (Cortype) In Neurological - Surgery, In the beginning of the article, historical considerations have been written, then specifications of laser light have been noted, including the functions of laser. In this article, types of laser have been matched. In the another part of article, advantages of Co2 . laser have been mentioned,...

متن کامل

Numerical Investigation of the Non-Uniformity of the Electric Field Distribution by Injection of Net Electron Charge in TE CO2 Laser

In this report, the distribution and deviation of electric field in the active medium of the TE CO2 laser has been investigated due to the injection of net electron charge beam as a plasma generator. Some parameters of system have been considered, such as density and mean-free-path of injected charge beam. The electric potential and electric field distribution have been simulated by solving the...

متن کامل

Investigation of the ultrasonic welding strength in glass fiber reinforced thermoset polymers with surface preparation method using laser beam

In this research, tensile strength of ultrasonic welded parts made of thermoset polymer-reinforced glass fiber with surface preparation has been investiagted. In order to elevate the adhesion of two surfaces laser grooving method has been applied. Two type of thermoplastic materials including Plymethyl methacrylate (PMMA) and polypropylene (PP) have been used as interlayers. Influences of main ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017