Variation in dengue virus plaque reduction neutralization testing: systematic review and pooled analysis

نویسندگان

  • Kaitlin Rainwater-Lovett
  • Isabel Rodriguez-Barraquer
  • Derek AT Cummings
  • Justin Lessler
چکیده

BACKGROUND The plaque reduction neutralization test (PRNT) remains the gold standard for the detection of serologic immune responses to dengue virus (DENV). While the basic concept of the PRNT remains constant, this test has evolved in multiple laboratories, introducing variation in materials and methods. Despite the importance of laboratory-to-laboratory comparability in DENV vaccine development, the effects of differing PRNT techniques on assay results, particularly the use of different dengue strains within a serotype, have not been fully characterized. METHODS We conducted a systematic review and pooled analysis of published literature reporting individual-level PRNT titers to identify factors associated with heterogeneity in PRNT results and compared variation between strains within DENV serotypes and between articles using hierarchical models. RESULTS The literature search and selection criteria identified 8 vaccine trials and 25 natural exposure studies reporting 4,411 titers from 605 individuals using 4 different neutralization percentages, 3 cell lines, 12 virus concentrations and 51 strains. Of 1,057 titers from primary DENV exposure, titers to the exposure serotype were consistently higher than titers to non-exposure serotypes. In contrast, titers from secondary DENV exposures (n = 628) demonstrated high titers to exposure and non-exposure serotypes. Additionally, PRNT titers from different strains within a serotype varied substantially. A pooled analysis of 1,689 titers demonstrated strain choice accounted for 8.04% (90% credible interval [CrI]: 3.05%, 15.7%) of between-titer variation after adjusting for secondary exposure, time since DENV exposure, vaccination and neutralization percentage. Differences between articles (a proxy for inter-laboratory differences) accounted for 50.7% (90% CrI: 30.8%, 71.6%) of between-titer variance. CONCLUSIONS As promising vaccine candidates arise, the lack of standardized assays among diagnostic and research laboratories make unbiased inferences about vaccine-induced protection difficult. Clearly defined, widely accessible reference reagents, proficiency testing or algorithms to adjust for protocol differences would be a useful first step in improving dengue PRNT comparability and quality assurance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization and Validation of a Plaque Reduction Neutralization Test for the Detection of Neutralizing Antibodies to Four Serotypes of Dengue Virus Used in Support of Dengue Vaccine Development

A dengue plaque reduction neutralization test (PRNT) to measure dengue serotype-specific neutralizing antibodies for all four virus serotypes was developed, optimized, and validated in accordance with guidelines for validation of bioanalytical test methods using human serum samples from dengue-infected persons and persons receiving a dengue vaccine candidate. Production and characterization of ...

متن کامل

Comparison of plaque- and flow cytometry-based methods for measuring dengue virus neutralization.

As dengue vaccines enter clinical trials, there is a need for rapid and quantitative assays to measure neutralization. We have developed flow-based neutralization assays which generated results similar to those generated by the established, plaque reduction neutralization test. The flow assays are an improvement, as they use human cells and allow for high-throughput screening.

متن کامل

Potential application of nonstructural protein NS1 serotype-specific immunoglobulin G enzyme-linked immunosorbent assay in the seroepidemiologic study of dengue virus infection: correlation of results with those of the plaque reduction neutralization test.

An NS1 serotype-specific indirect enzyme-linked immunosorbent assay (ELISA) was developed to differentiate primary and secondary dengue virus infections and serotypes of primary dengue virus infection. For this report, we carried out retrospective seroepidemiologic studies on serum samples collected from residents of Liuchiu Hsiang, Pingtung County, an isolated island in southern Taiwan during ...

متن کامل

Simplified plaque reduction neutralization assay for dengue viruses by semimicro methods in BHK-21 cells: comparison of the BHK suspension test with standard plaque reduction neutralization.

A newly modified semimicro plaque reduction neutralization test (PRNT) in BHK cells was compared with a standard PRNT in bottles with LLC-MK2 monolayers and with an LLC-MK2 PRNT adapted to semimicro methods. The BHK semimicro PRNT compared favorably in terms of sensitivity in detecting dengue antibody (96%), specificity at a screening dilution (95%), and ability to detect seroconversion to deng...

متن کامل

Persistence of Neutralizing Antibody Against Dengue Virus 2 After 70 Years from Infection in Nagasaki

This study aimed to investigate the duration of humoral immune responses to dengue virus (DENV) infection in Japanese who experienced acute febrile illness with hemorrhagic manifestations 70 years ago, when an epidemic of dengue occurred in Nagasaki, Japan, from 1942 to 1944. A Japanese volunteer requested serological diagnosis of DENV infection in 2014 and donated blood sample to measure the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012