Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
نویسندگان
چکیده
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 patients treated with BP-BES and 1,000 patients treated with DP-EES. The primary outcome was target lesion failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization. Definite or probable stent thrombosis was also compared in total and propensity score-matched cohorts. The median follow-up duration was 24 months, and mean age was 65 years (interquartile range, 56-72 years). Patients receiving BP-BES had a lower prevalence of acute coronary syndrome, prior myocardial infarction, multi-vessel disease, bifurcation lesions, and left anterior descending artery lesions than those receiving DP-EES. After propensity score matching (692 pairs), target lesion failure occurred in 22 patients receiving BP-BES and in 25 patients receiving DP-EES (3.2% versus 3.6%; adjusted hazard ratio [HR], 0.92; 95% confidence interval [CI], 0.53 to 1.60; p = 0.77). The risk of definite or probable stent thrombosis did not differ between the 2 groups (0.4% versus 0.4%; adjusted HR, 1.03; 95% CI, 0.21 to 4.98; p = 0.97). The results were consistent across various subgroups. In the propensity score-matched analysis of real world cohorts, BP-BES showed similar clinical outcomes compared to DP-EES. We need to investigate about whether differences in clinical outcome emerge during long-term follow-up.
منابع مشابه
The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.
INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...
متن کاملTwo-year outcome of a randomized trial comparing second-generation drug-eluting stents using biodegradable or durable polymer.
Two-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Biodegradable or Durable Polymer Recentnetworkmeta-analyseshave raisedconcerns about the safety of biodegradable polymerdrug-eluting stents (BP-DES) compared with durable polymer everolimus-eluting stents (DP-EES).1-3 The NOBORI Biolimus-Eluting vs XIENCE/ PROMUSEverolimus-ElutingStentTrial (NEXT) is a9...
متن کاملSafety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis
OBJECTIVES To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). DESIGN Network meta-analysis of randomised controlled trials. DATA SOURCES AND STUDY SELECTION Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled tr...
متن کاملAcute Thrombogenicity of a Durable Polymer Everolimus-Eluting Stent Relative to Contemporary Drug-Eluting Stents With Biodegradable Polymer Coatings Assessed Ex Vivo in a Swine Shunt Model.
OBJECTIVES This study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model. BACKGROUND Previous pre-clinical and clinical experience suggests that several factors may influenc...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کامل