Wavelength Selection for Near-Infrared Spectroscopic Analysis of Teicoplanin
نویسندگان
چکیده
Teicoplanin (TCP) is a multiple drug-resistant lipoglycopeptide antibiotic produced by fermenting Actinoplanes teichomyceticus. In this study, a mixture of TCP with the Tris-HCl buffer (TCP-TrisHCl) was used to simulate TCP fermentation broth. The reagent-free, rapid and simultaneous quantitative analysis models for TCP and Tris in the TCP-Tris-HCl mixtures were established by nearinfrared (NIR) spectroscopy. The equidistant combination partial least squares (EC-PLS) method and the equivalent model sets were proposed, the simplest equivalent model with the smallest number of wavelengths were further selected. The initial wavelength, number of wavelengths, number of wavelength gaps, number of PLS factors were 1520 nm, 28, 5, 5 for TCP and 1084 nm, 13, 6, 4 for Tris, respectively. Compared with the optimal EC-PLS models, the simplest equivalent models adopted fewer wavelengths. Thus, the redundant wavelengths were removed, the models were further simplified. The root-mean-square errors (SEP) and correlation coefficients (RP) for prediction were 0.043 mg∙mL−1 and 0.9998 for TCP, and 0.222 mg∙mL−1 and 0.9989 for Tris, respectively. The results indicate that NIR method can be applied to highly accurate quantitative analysis for TCP and provide valuable references for further application to TCP fermentation broth.
منابع مشابه
Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and near-infrared spectroscopic data.
A new wavelength interval selection procedure, moving window partial least-squares regression (MWPLSR), is proposed for multicomponent spectral analysis. This procedure builds a series of PLS models in a window that moves over the whole spectral region and then locates useful spectral intervals in terms of the least complexity of PLS models reaching a desired error level. Based on a proposed th...
متن کاملEvaluation of Reflection Optical Imaging Characteristics Using Fluorescence with Near Infrared Wavelength at Different Depths of Tissue Equivalent Phantom
متن کامل
Bioreactor monitoring with spectroscopy and chemometrics: a review.
Biotechnological processes are crucial to the development of any economy striving to ensure a relevant position in future markets. The cultivation of microorganisms in bioreactors is one of the most important unit operations of biotechnological processes, and real-time monitoring of bioreactors is essential for effective bioprocess control. In this review, published material on the potential ap...
متن کاملPretreatment and Wavelength Selection Method for Near-Infrared Spectra Signal Based on Improved CEEMDAN Energy Entropy and Permutation Entropy
The noise of near-infrared spectra and spectral information redundancy can affect the accuracy of calibration and prediction models in near-infrared analytical technology. To address this problem, the improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) and permutation entropy (PE) were used to propose a new method for pretreatment and wavelength selection of ne...
متن کاملUninformative Biological Variability Elimination in Apple Soluble Solids Content Inspection by Using Fourier Transform Near-Infrared Spectroscopy Combined with Multivariate Analysis and Wavelength Selection Algorithm
Uninformative biological variability elimination methods were studied in the near-infrared calibration model for predicting the soluble solids content of apples. Four different preprocessing methods, namely, Savitzky-Golay smoothing, multiplicative scatter correction, standard normal variate, and mean normalization, as well as their combinations were conducted on raw Fourier transform near-infr...
متن کامل