Variable reduction algorithm for atomic emission spectra: application to multivariate calibration and quantitative analysis of industrial samples

نویسندگان

  • Michael L. Griffiths
  • Daniel Svozil
  • Paul Worsfold
  • Sue Denham
  • Hywel Evans
چکیده

A variable selection procedure has been developed and used to reduce the number of wavelength data points necessary to formulate a predictive multivariate model for Pt, Pd and Rh using full atomic emission spectra (5684 wavelength data points per spectrum) obtained using a Segmented-Array Charge-Coupled Device Detector (SCCD) for inductively coupled plasma atomic emission spectrometry (ICP-AES). The first stage was the application of an Uninformative Variable Elimination Partial Least Squares (UVE-PLS) algorithm which identified the PLS regression coefficients that are equal to zero at a specified significance level, and removed the associated variables. The second stage was the application of an Informative Variable Degradation PLS (IVD) algorithm, which ranked variables using the ratio of their PLS mean regression coefficients and regression coefficient estimated standard errors (estimated using the jackknife). Variable selection was then achieved by examination of the cumulative sum of these ratios. The algorithms were applied to emission spectra for the determination of Pt, Pd and Rh in a synthetic matrix (Al, Mg, Ce, Zr, Ba, In, Sc and Y at various concentrations). The variable selection routines reduced 5684 wavelength data points to 47, 110 and 334 and gave relative root mean square error (RRMSE) values of 4.60, 3.20 and 1.65% for Pt, Pd and Rh, respectively, compared with 12.6, 8.32 and 27.2% obtained using all 5684 data points; and 5.19, 7.06 and 3.18% obtained when using 166 pre-selected, integrated atomic emission lines. There was no requirement for wavelength or background correction point selection or for wavelength alignment because the entire available segmented spectrum was used in the calibration model. This approach was extended by using real industrial fusion samples to build a calibration model in order to predict the concentration of Au, Ag and Pd in similar matrices. RRMSEs of 23, 29 and 9.1% were obtained for the respective elements in test samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Application of Genetic Algorithms for Pixel Selection in MIA-QSAR Studies on Anti-HIV HEPT Analogues for New Design Derivatives

Quantitative structure-activity relationship (QSAR) analysis has been carried out with a series of 107 anti-HIV HEPT compounds with antiviral activity, which was performed by chemometrics methods. Bi-dimensional images were used to calculate some pixels and multivariate image analysis was applied to QSAR modelling of the anti-HIV potential of HEPT analogues by means of multivariate calibration,...

متن کامل

Application of Genetic Algorithms for Pixel Selection in MIA-QSAR Studies on Anti-HIV HEPT Analogues for New Design Derivatives

Quantitative structure-activity relationship (QSAR) analysis has been carried out with a series of 107 anti-HIV HEPT compounds with antiviral activity, which was performed by chemometrics methods. Bi-dimensional images were used to calculate some pixels and multivariate image analysis was applied to QSAR modelling of the anti-HIV potential of HEPT analogues by means of multivariate calibration,...

متن کامل

Linear and Nonlinear Multivariate Classification of Iranian Bottled Mineral Waters According to Their Elemental Content Determined by ICP-OES

The combinations of inductively coupled plasma-optical emission spectrometry (ICP-OES) and three classification algorithms, i.e., partial least squares discriminant analysis (PLS-DA), least squares support vector machine (LS-SVM) and soft independent modeling of class analogies (SIMCA), for discriminating different brands of Iranian bottled mineral waters, were explored. ICP-OES was used for th...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002