Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography.
نویسندگان
چکیده
OBJECTIVES To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. METHODS The CBCT units used were Veraviewepocs 3De(®) (J Morita MFG Corp., Kyoto, Japan), ProMax(®) 3D (Planmeca, Helsinki, Finland) and NewTom VGi(®) (Quantitative Radiology, Verona, Italy). GafChromic XR-QA2 films were placed between the selected layers of the head and neck of a tissue-equivalent human skull (RANDO(®) phantom; The Phantom Laboratory, Salem, NY). The exposure parameters were set using the automatic exposure control function of the units. Depending on the availability, medium and smaller field of view (FOV) scanning modes were used. The effective dose was estimated using the 2007 International Commission on Radiological Protection formalism. RESULTS The lowest effective dose of a CBCT unit was observed for ProMax 3D, FOV 4 × 5 cm (10 μSv), the highest for NewTom VGi, FOV 8 × 8 cm-high resolution (129 μSv). The range of effective doses for digital panoramic machines measured was 8-14 μSv. CONCLUSIONS This study demonstrates the feasibility of using radiochromic films for dental CBCT and panoramic dosimetry.
منابع مشابه
Estimating and comparing the radiation cancer risk from cone-beam computed tomography and panoramic radiography in pediatric and adult patients
Background: This study aimed to estimate and compare the absorbed dose, lifetime cancer risk and mortalities due to cone-beam computed tomography (CBCT) and panoramic examinations on patients. Materials and Methods: The exposure factors were applied to 332 patients in two age groups (6-10, and ˃18-year-old). The dose-area product (DAP) values were measured for CBCT and panoramic radiographies. ...
متن کاملGafChromic XR‐QA film in testing panoramic dental radiography
The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...
متن کاملEvaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...
متن کاملبررسی مقایسهای دوز جذبی اشعه در اندامهای هدف درتصویربرداری از ناحیه فک و صورت با تکنیکهای پانورامیک، توموگرافی خطی، CBCT و CT پزشکی
Background and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT) and computed tomography (CT).Materials and Methods: Thermoluminescent dosimeters (TLD) were implanted in 14 sites of RANDO phantom to measu...
متن کاملEvaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines
Introduction: Maxillary canines have important roles in facial appearance, development of arch, and functional occlusion. Radiographs are important in evaluating the location and nature of these anomalies. The purpose of this study was to evaluate two types of 2D and 3D imaging technique in diagnosis and treatment of maxillary impacted canines. Methods: Thirty eight patients (50 impacted canine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Dento maxillo facial radiology
دوره 42 7 شماره
صفحات -
تاریخ انتشار 2013