Relative bioavailability of salbutamol to the lung following inhalation using metered dose inhalation methods and spacer devices.

نویسندگان

  • M Hindle
  • H Chrystyn
چکیده

BACKGROUND Inhalation aids do not require coordination between actuation of a metered dose inhaler (MDI) with inspiration and reduce oropharyngeal impaction. The delivery of salbutamol to the lung and systemic availability following inhalation with three commonly used spacers and an open mouth technique have been evaluated using a simple noninvasive technique based on urinary excretion 30 minutes and 24 hours after the dose. METHODS Ten healthy subjects inhaled, on randomised study days, 4 x 100 micrograms from a Ventolin MDI and, subsequently, with the aid of a Volumatic, Bricanyl Spacer, and Nebuhaler spacer device. In addition, an open mouth inhaler technique was evaluated. Urine samples were collected 0-30 minutes and 0.5-24 hours after inhalation. From these samples the relative bioavailability to the lung (urinary salbutamol excretion 30 minutes after dosing) and the systemic bioavailability of the dose (24 hour urinary excretion of salbutamol and its metabolite) for each inhalation method was obtained. RESULTS The mean (SD) urinary excretion of salbutamol 30 minutes after inhalation using the MDI alone and with the Volumatic, Bricanyl Spacer, Nebuhaler, and open mouth technique was 2.83 (0.78)%, 3.37 (0.69)%, 4.09 (0.91)%, 4.34 (1.60)%, and 3.49 (0.98)%, respectively, expressed as a percentage of the nominal dose. The nebuhaler and Bricanyl Spacer spacer devices were found to increase the relative bioavailability of salbutamol to the lung compared with the MDI alone. Compared with the MDI the inhalation aid increases were much greater than the intra-individual variability of the urinary excretion method. In 11 individuals who each repeated the same inhalation procedure on four separate occasions, the mean (SD) coefficient of variation was 8.24 (2.36)%. The mean (SD) 24 hour urinary excretion of salbutamol and its metabolites was 26.6 (6.79), 27.0 (7.95), and 55.6 (9.74)% of the salbutamol dose for the Volumatic, Nebuhaler, and MDI, respectively. Similar values following the open mouth method and Bricanyl Spacer were 48.9 (10.97)% and 43.8 (11.57)%. These values, representing the systemic availability of the inhaled dose, were lower when inhaling with the aid of the Volumatic and Nebuhaler than inhalation from the MDI alone. CONCLUSIONS Spacer devices improve pulmonary bioavailability of salbutamol and reduce the systemically available dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigations of an optimal inhaler technique with the use of urinary salbutamol excretion as a measure of relative bioavailability to the lung.

BACKGROUND A simple non-invasive method, in which a urine sample is taken 30 minutes after drug administration, has previously been shown to be a measure of the relative bioavailability of salbutamol to the lungs. This technique has been used to determine an optimal inhaler technique with commercially available metered dose inhalers (MDI). METHODS Ten healthy subjects were trained in the use ...

متن کامل

Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device.

BACKGROUND The aim of this study was to extend previous in vitro observations regarding the effects of multiple actuations of aerosols into spacer devices, delayed inhalation, and antistatic treatment of spacer devices on the amount of drug delivered for inhalation. An in vivo study of lung bioavailability of salbutamol from a large volume (Volumatic) spacer was conducted. METHODS Ten healthy...

متن کامل

Volumatic usage: some generic salbutamol metered dose inhalers can be used.

BACKGROUND The 30 minute and 24 hour post-inhalation urinary excretion of salbutamol represents the relative amount of drug deposited in the lungs and total systemic absorption, respectively. Using this method two metered dose inhalers used with a Volumatic (Allen and Hanburys Ltd, UK) large volume spacer have been compared. METHOD Eleven healthy volunteers inhaled 4 x 100 micrograms salbutam...

متن کامل

The Bioavailability of Salbutamol in Urine via Volumatic and Nonvolumatic Valved Holding Chambers

PURPOSE Pressurized metered dose inhalers are commonly used in patients with asthma. However, the need to coordinate inhalation with inhaler actuation means that they are not suitable for use per se. Valved holding chamber devices were developed to overcome some of the problems of pressurized metered dose inhalers. Several types of holding chambers of different sizes are available in Iran. This...

متن کامل

Salbutamol metered-dose inhaler with spacer for hyperkalemia: how fast? How safe?

OBJECTIVE To determine the efficacy of inhaled salbutamol (rapidly delivered, using a metered-dose inhaler with a spacer device [MDI-S]) in lowering the serum potassium levels in patients with hyperkalemia. DESIGN A randomized, double-blind, placebo-controlled trial. PATIENTS Seventeen chronic renal failure patients referred to the Nephrology Unit between October 1, 1997 and March 31, 1998 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 49 6  شماره 

صفحات  -

تاریخ انتشار 1994