Dimensional stability of distances between teeth in complete dentures comparing microwave polymerization and conventional cycles
نویسندگان
چکیده
Aim: This study investigated the tooth movement of complete dentures processed by microwave activation and conventional processing method in water bath. Methods: Twenty maxillary complete dentures were fabricated and randomly assigned to 4 groups (n=5): Group I: Classico conventional heat-curing acrylic resin processed by microwave polymerization; Group II: Classico resin processed in water bath at 74°C for 9 h (control-group); Group III: QC-20 fast heat-curing acrylic resin processed in boiling water for 20 min; Group IV: Onda-Cryl microwave acrylic resin processed at the same conditions of Group 1. Metallic referential pins were placed on the incisal border of the central incisors, buccal cusp of the first premolars, and the mesiobuccal cusp of the second molars. Transversal and anteroposterior distances were measured before and after the complete dentures processing with a linear optical microscope (Olympus Optical Co., Tokyo, Japan) accurate to 0.0005 mm. Data were subjected to ANOVA and Tukey’s test at 5% significance levels. Results: Inside each group, dentures showed some tooth movement but without statistical difference before and after the polymerization. Conclusions: Dentures processed by microwave energy presented similar performance to those subjected to conventional cycles in water bath for most of distances evaluated.
منابع مشابه
Effect of polymerization techniques on vertical dimension and tooth position in complete dentures.
Due to the changes in the composition and processing of acrylic resins, it seems appropriate to evaluate the influence of polymerization methods about the alteration of occlusal vertical dimension and the horizontal positioning of artificial teeth of total dentures. For this, 64 specimens were made, simulating a maxillary total denture waxed from a standard maxillary denture. The experimental s...
متن کاملThe role of polymerization cycle and post-pressing time on tooth movement in complete dentures.
This study analyzed the influence of polymerization cycle and post-pressing time on tooth movement in complete dentures. Forty maxillary complete dentures were fabricated and randomly assigned to 8 groups (n = 5); the polymerization cycle (conventional long cycle in water bath, fast cycle in boiling water, and by microwave energy) and the post-pressing time (immediate and 6 hours) were varied. ...
متن کاملEffect of Stone Cast Type on Complete Denture Base Adaptation
Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...
متن کاملEffect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
The purpose of this study was to verify the influence of flask closure methods and post-pressing times on tooth displacement in maxillary dentures. Twenty similar maxillary dentures were made using a heat-polymerized acrylic resin, and randomly assigned to 4 experimental groups (n=5) according to the protocol: 1-conventional flask closure and immediate polymerization; 2- conventional flask clos...
متن کاملEffect of the flask contention method on the displacement of maxillary denture teeth
Correspondence to: Wagner Araújo de Negreiros University of Campinas – Piracicaba Dental School Department of Prosthodontics and Periodontology Av. Limeira 901, CEP: 13414-903 Piracicaba Brazil Telephone: (19) 3435-1233 E-mail: [email protected] Abstract Keeping the flask closed may reduce the stress released by the resin dough after the pressing step, preserving the tooth relationship ...
متن کامل