The influence of central corneal thickness on intraocular pressure measured by goldmann applanation tonometry among selected Ethiopian communities.
نویسندگان
چکیده
BACKGROUND Estimates of intraocular pressure (IOP) are influenced directly by the central corneal thickness (CCT). We assume and apply a single value for CCT (520 μm) in applanation tonometry estimates, although there is compelling evidence that CCT varies between individuals. OBJECTIVE To determine the influence of CCT and other factors on IOP among Ethiopians. METHODS A cross sectional study was conducted among 300 sampled individuals from June to July 2006. The CCT was measured using OcuScan® R×P Ophthalmic Ultrasound and readings of IOP were made with Goldmann applanation tonometer. The data was analyzed using SPSS version 12 and S-Plus 2000 of statistical packages. RESULTS Out of 300 individuals, 184 (61.3%) were males. The mean age was 42.57 years (SD±16.71), mean IOP 13.39 mm Hg (SD±2.81), and mean CCT 518.68 μm (SD±32.92). There was statistically significant relationship between CCT and IOP (r=0.199, P<0.001) and a borderline statistically significant detectable change of CCT with age (r=0.012, P=0.057) with a downward trend of at least 0.001 mm decrease in CCT/decade starting from age 30 years but with pronounced change from 50 years onward. For every 30 μm difference in CCT from the mean in either way, there was an approximately 1.1 mm Hg difference in the estimated IOP from the mean IOP (13.40 mm Hg). No significant relationship was found between IOP and age, sex or ethnicity (P>0.05). CONCLUSION The CCT of Ethiopians is thin and hence can result in underestimation of IOP measured by GAT.
منابع مشابه
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملThe impact of central corneal thickness on intraocular pressure among Ethiopian glaucoma patients: a cross-sectional study
BACKGROUND Raised intraocular pressure (IOP) is the only causal risk factor for glaucoma that can be therapeutically manipulated to change the course of the disease process. Though Goldman applanation tonometry (GAT) is the "gold standard" for IOP measurement, readings of IOP with GAT are affected by central corneal thickness (CCT). The aim of this study is to determine the impact of CCT on IOP...
متن کاملPressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.
PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...
متن کاملComparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature
PURPOSE The aim of the study was to assess the influence of central corneal thickness (CCT) and corneal curvature in tonometry measurements taken by Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT). METHODS This was a prospective study of 185 eyes from 97 subjects, attending outpatient ophthalmology appointments, who underwent intraocular pressure measurements b...
متن کاملOcular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements.
PURPOSE To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central cornea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of glaucoma
دوره 19 8 شماره
صفحات -
تاریخ انتشار 2010