Risk of cancer with metal-on-metal hip replacements: population based study

نویسندگان

  • Keijo T Mäkelä
  • Tuomo Visuri
  • Pekka Pulkkinen
  • Antti Eskelinen
  • Ville Remes
  • Petri Virolainen
  • Mika Junnila
  • Eero Pukkala
چکیده

OBJECTIVE To assess the risk of cancer associated with modern primary metal-on-metal hip replacements. DESIGN Population based study. SETTING Nationwide retrospective comparative register. PARTICIPANTS 10,728 patients who underwent metal-on-metal total hip arthroplasty and 18,235 patients who underwent conventional metal-on-polyethylene, ceramic-on-polyethylene, and ceramic-on-ceramic total hip arthroplasty (the non-metal-on-metal cohort) in the Finnish Arthroplasty Register 2001-10. Data on cancer cases up to 2010 for these cohorts were extracted from the Finnish Cancer Registry. MAIN OUTCOME MEASURES The relative risk of cancer was expressed as the ratio of observed to expected number of cases from the Finnish population--that is, the standardised incidence ratio. The relative risk of cancer in the metal-on-metal cohort compared with the non-metal-on-metal cohort was estimated with analyses of these ratios and Poisson regression. RESULTS The overall risk of cancer in patients with metal-on-metal hip implants was similar to that in the Finnish population (378 observed v 400 expected, standardised incidence ratio 0.95, 95% confidence interval 0.85 to 1.04). The overall risk of cancer in patients with metal-on-metal hip implants was also no higher than in patients who had received non-metal-on-metal hip implants (relative risk 0.92, 0.81 to 1.05). CONCLUSIONS Metal-on-metal hip replacements are not associated with an increased overall risk of cancer during a mean follow-up of four years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patterns of Risk of Cancer in Patients with Metal-on-Metal Hip Replacements versus Other Bearing Surface Types: A Record Linkage Study between a Prospective Joint Registry and General Practice Electronic Health Records in England

BACKGROUND There are concerns that metal-on-metal hip implants may cause cancer. The objective of this study was to evaluate patterns and timing of risk of cancer in patients with metal-on-metal total hip replacements (THR). METHODS In a linkage study between the English National Joint Registry (NJR) and the Clinical Practice Research Datalink (CPRD), we selected all THR surgeries (NJR) betwe...

متن کامل

Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland

BACKGROUND AND PURPOSE Metal-on-metal hip implants have been widely used, especially in the USA, Australia, England and Wales, and Finland. We assessed risk of death and updated data on the risk of cancer related to metal-on-metal hip replacements. PATIENTS AND METHODS A cohort of 10,728 metal-on-metal hip replacement patients and a reference cohort of 18,235 conventional total hip replacemen...

متن کامل

The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip ...

متن کامل

Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man

BACKGROUND Adverse reactions to metal debris (ARMD) have resulted in the high short-term failure rates observed with metal-on-metal hip replacements. ARMD has recently been reported in non-metal-on-metal total hip replacements (non-MoM THRs) in a number of small cohort studies. However the true magnitude of this complication in non-MoM THRs remains unknown. We used a nationwide database to dete...

متن کامل

Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia.

We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 345  شماره 

صفحات  -

تاریخ انتشار 2012