Analysis of breath alcohol via infrared spectrophotometry: predicting false ethanol results by application of the base-line method to vapor phase infrared spectra.

نویسنده

  • D A Labianca
چکیده

Toluene and a mixture of the isomeric xylenes are common organic solvents that have been implicated in false ethanol results produced by older models of the Intoxilyzer 5000, a breath alcohol analyzer that uses infrared spectrophotometry to quantitate ethanol in breath samples. A straightforward method is described which predicts this type of interference in analyses conducted on such models. The methodology relies on a comparison of the vapor phase infrared spectra of toluene and xylene with the corresponding spectrum of ethanol, using the base-line method to estimate relative absorbances at the two analytical wavelengths employed by the Intoxilyzer 5000. The point is also made that, given the potential for such interference, a model of the Intoxilyzer 5000 has been developed that has the capability to compensate for this problem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field performance of current generation breath-alcohol simulators.

The between-run accuracy and reproducibility of vapor-alcohol control tests associated with quantitative evidential breath-alcohol testing in the field were evaluated. Control samples were generated at six separate sites with 34 degrees C TOXITEST II breath-alcohol simulators and analyzed by infrared spectrometry with Model 5000-D intoxilyzers in the recirculation mode. Control test results at ...

متن کامل

Acetone Expiration and Breath-alcohol Testing

In many countries breath-alcohol testing is a well established method to control driving under the influence of alcohol. Various analytical principles are used to measure the alcohol concentration in expired breath, such as gas chromatography, electrochemical cells, semiconductors, and infrared spectrometry. A breath-alcohol analyzer based on the last method was demonstrated at the last meeting...

متن کامل

Predicting of Effective Dose as Biomarker for Cytotoxicity Using Partial Least Square-Fourier Transform Infrared Spectroscopy (PLS_FTIR)

Toxicity bioassays are important tools to determine biological effects of chemical agents on species. The questions remained on, what effects have been imposed on each of the different molecular site of cells by chemical exposure and how to find a pattern for chemical toxicity. To address the questions, HepG2 cell lines were exposed to the different concentrations of cisplatin for 24 hours to r...

متن کامل

Predicting of Effective Dose as Biomarker for Cytotoxicity Using Partial Least Square-Fourier Transform Infrared Spectroscopy (PLS_FTIR)

Toxicity bioassays are important tools to determine biological effects of chemical agents on species. The questions remained on, what effects have been imposed on each of the different molecular site of cells by chemical exposure and how to find a pattern for chemical toxicity. To address the questions, HepG2 cell lines were exposed to the different concentrations of cisplatin for 24 hours to r...

متن کامل

Measuring Alcohol in Blood and Breath for Forensic Purposes - A Historical Review.

This review concerns important events and trends in the evolution of chemical tests for alcohol intoxication on two continents; Europe and North America. In particular, the pioneer workers in this field and their major contributions to forensic alcohol analysis are emphasized. Quantitative methods for the determination of alcohol in blood, breath, and urine appeared early in the twentieth centu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 1996