Evaluating the use of robotically assisted percutaneous coronary intervention: a matter of being precise

نویسندگان

  • Nathaniel R Smilowitz
  • Giora Weisz
چکیده

Since the advent of catheter-based coronary intervention three decades ago, steady technological progress has led to the development and refinement of intracoronary devices [1]. Despite technological advances, the fundamental workflow of coronary procedures remains unchanged. Interventionalists still wear heavy protective lead aprons, stand at the bedside for long hours and manually manipulate catheters and intra vascular devices under direct fluoroscopic guidance. As the field has matured, greater attention has been paid to the long-term occupational hazards of this antiquated interventional approach [2]. A striking prevalence of orthopedic injuries and spinal disc disease has been reported following hours of standing under heavy lead aprons [3,4]. Although radiation badges worn by inter ventional personnel can help track and limit exposure, any radiation exposure may be harmful, and risks of solid or hematologic malignancy continue to be a significant concern [5,6]. A high prevalence of posterior lens radiation injuries leads to earlier cataracts among interventionalists and provides additional incentive to minimize ionizing radiation exposure [7]. Given the clear risks of modern practice, remotecontrol robotic catheter-based systems were first proposed to mitigate occupational hazards in percutaneous coronary interventions (PCIs). Beyar et al. developed the first-generation ‘Remote Navigation System’ for PCI (Remote Navigation System, NaviCath, Haifa, Israel), consisting of a joystick controlled operator module and motorized drive to advance and retrieve intravascular devices mounted on the procedure table. A small clinical pilot study demonstrated the feasibility and safety of this robotic system for single-vessel PCI [8,9]. Following this early study, the Robotic Navigation System was redesigned as the CorPath System (Corindus Vascular Robotics, MA, USA).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and feasibility of robotic percutaneous coronary intervention: PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study.

OBJECTIVES The aim of this study was to evaluate the safety as well as the clinical and technical effectiveness of robotic-assisted percutaneous coronary intervention. BACKGROUND Robotic systems have been suggested to enhance the performance of cardiovascular procedures, as well as to provide protection from the occupational hazards that are associated with interventional practice. METHODS ...

متن کامل

اثر PercutaneousCoronary Intervention Elective بر بهبودی نارسایی ایسکمیک میترال

Introdution: Ischemic mitral regurgitation (IMR) remains one of the most complex and unresolved aspects of ischemic heart disease that the impact of percutaneous coronary intervention (PCI) on improvement of intensity of ischemic mitral regurgitation is not well clarified. Patients with coronary artery diseases and ischemic mitral regurgitation have a worse prognosis than the patients with coro...

متن کامل

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure after percutaneous coronary intervention.Material and Methods: Fifty patients with left ventricular ejection fraction ≤ 40% undergone percutaneous coronary intervention were r...

متن کامل

Overconsumption of contrast media in percutaneous coronary intervention: Focusing on cost and acute kidney injury

Irrational use of medicines is a major problem worldwide. Since iodixanol (Visipaque®) was categorized in Category I (AV) based on the ABC-VED analysis in our hospital, we evaluated the amount of visipaque use and estimated the incremental cost based on the maximum contrast dose (MCD) following irrational use of contrast media. This retrospective study was conducted on 100 admitted patients age...

متن کامل

Effect of Jacobson's relaxation on anxiety in patients undergoing percutaneous coronary intervention

Introduction: Anxiety is common in patients undergoing percutaneous coronary intervention. Some studies have shown that one of the decreasing factors in anxiety is relaxation. Importantly, this study has been done with the aim of investigate the effect of Jacobson's relaxation on anxiety in patients undergoing percutaneous coronary intervention. Materials and Methods: In this double-blind clini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012