Feasibility of mitral flow assessment by echo-contrast ultrasound, part II: experimental study on a mechanical model of the left heart.

نویسندگان

  • B Herman
  • S Einav
  • Z Vered
چکیده

The feasibility of assessing mitral flow by means of ultrasonic monitoring of backscattered power from an echo-contrast agent in the left atrium and left ventricle was studied. A mechanical model of the left heart was built in which two thin rubber balloons connected to each other in a feedback loop via two artificial heart valves mimicked the left atrium and left ventricle. The model was driven by compressed air. Its input and output flows were measured as the functions of a pacing rate, driving pressure and artificially introduced mitral regurgitation. These were compared with the corresponding data derived from the ultrasonic measurements that are based on the correlation between echo-contrast agent concentration in the volume of interest and the flow through it. Algorithms for quantitative estimations of forward stroke volume (cardiac output) and mitral regurgitation are given. This study shows, for the first time, both analytically and experimentally, that the pulsating modulation of contrast agent concentration vs. time curves in the ventricle and atrium volumes is closely related to the pulsating nature of the flow in the system. It also shows that the amplitude of the atrium concentration modulation is directly proportional to the maximum value of the incoming (to atrium) flow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

Feasibility of mitral flow assessment by echo-contrast ultrasound, part I: determination of the properties of echo-contrast agents.

Data on the ultrasonic properties of commercially available contrast agents are limited by being instrument-dependent, especially with regard to their backscattering properties. The present work describes methods of measurements that provide instrument-independent estimations of a contrast agent's attenuation coefficient and integrated backscatter index and provide them as functions of its conc...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Black Defects in Severe Spontaneous Echo Contrast Teach Us the Protective Aspect of Mitral Regurgitation Visually

A 74-year-old Japanese female was diagnosed as chronic atrial fibrillation, and anticoagulant therapy with warfarin started. One year after anticoagulant therapy, she was referred to our center for evaluation of cardiac function. Transthoracic echocardiography by Philips iE33 ultrasound system with S5-1 transducer (USA) revealed huge left atrial thrombus (53 × 36 mm) (Fig. 1A). Left ventricular...

متن کامل

Evaluation of diastolic blood flow dynamic of the left ventricle in dogs with mitral valve regurgitation using vector flow mapping

Mitral valve regurgitation (MVR) is a common valvular disease in dogs. Hydrokinetic evaluation of the blood flow within the ventricles has become possible by vector flow mapping (VFM), which shows the blood flow within the ventricles in vector and vortex flows. Blood flow within the left ventricle of MVR dogs was compared at different stages of MVR and to that of normal dogs. 14 normal dogs and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2000