Comparative Assessment of Different Energy Mapping Approaches in CT Based Attenuation Correction: a Patient Study

نویسندگان

  • M. Shirmohammad
  • M. R. Ay
  • S. Sarkar
  • A. Rahmim
  • H. Zaidi
چکیده

Attenuation correction of PET emission data using spatially correlated CT images is fast and precise yielding a noise-free attenuation map (μmap) in comparison with radionuclide transmission scanning (TX). However, it is essential to convert the linear attenuation coefficients obtained from CT scans to those corresponding to 511 keV. Several conversion strategies have been developed including scaling, segmentation, hybrid and bilinear methods. The aim of this study is to compare the accuracy of different energy mapping methods for generation of 511 keV μmap using clinical studies. The procedure for generation of attenuation map from CT images using different energy mapping methods was assessed using clinical studies and the results compared to the TX image derived using Ga-68 rod sources acquired on the Discovery LS PET/CT scanner, were used as gold standard in this study. A region of interest analysis was performed at different locations of the μmaps. It was shown that for soft tissues, the relative difference of scaling, segmentation, hybrid and bilinear methods compared to TX technique were 11.3%, 9.2%, 11.3% and 10.8% respectively (no major difference). For bony structures, the quantitative analysis showed that the scaling method produces a substantial relative difference (31%). The relative difference of segmentation, hybrid and bilinear methods compared to TX were 29%, 14% and 18% respectively. However these results for lung tissue were 4%, 13%, 4% and 4% respectively for scaling, segmentation, hybrid and bilinear methods with a great difference for segmentation method. It can be concluded that for soft tissues all energy mapping methods give satisfactory results. For bone, the scaling and segmentation methods yield substantial relative differences but the other 2 methods give acceptable results. For lung tissue the results are approximately close to each other except for segmentation method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008